2.1Configuration Guidelines
Use the following guidelines to install and cable or reconfigure your StorEdge A3500FC system.
Caution –The onboard SOC+ on the I/O board is not qualified yet to work with the StorEdge A3500FC controller module.
Caution –At this time, only single port connection is qualified on the dual-ported host bus adapter card.
■The part number for the 15 meter FC-AL host cable is 595-3379-xx; the Marketing part number is X978A.
■Do not exceed a fiber-optic cable length of 500 meters (1640.5 feet).
■Install 16-bit, differential terminators to both HOST IN connectors on the back of the controller module (FIGURE 2-1).
Differential SCSI terminators—HOST IN
FIGURE 2-1Differential SCSI Terminators on Rear of Controller Module
2-2Sun StorEdge A3500/A3500FC Hardware Configuration Guide • December 1999