SUPER MICRO Computer 6015B-T, 6015B-3 Serial Ports, Power Supply Fail Header, Fan Headers

Models: 6015B-3 6015B-T

1 144
Download 144 pages 3.44 Kb
Page 49
Image 49

Chapter 5: Advanced Serverboard Setup

Serial Ports

Serial Port Pin Definitions

(COM1, COM2)

The COM1 serial port is located on the IO backplane. COM2 is a header on the serverboard (see serverboard layout for location). See the table on the right for pin defi nitions.

Pin # Defi nition

1DCD

2RXD

3TXD

4DTR

5Ground

Pin # Defi nition

6DSR

7RTS

8CTS

9RI

10 NC

Power Supply Fail Header

Connect a cable from your power sup- ply to the Power Fail header to provide you with warning of a power supply failure. The warning signal is passed through the PWR_LED pin to indicate a power failure. See the table on the right for pin defi nitions.

Note: Pin 10 is included on the header but not on the port. NC indicates no connection.

Power Supply Fail Header

Pin Definitions (JPWF)

Pin# Defi nition

1P/S 1 Fail Signal

2P/S 2 Fail Signal

3 P/S 3 Fail Signal

4 Alarm Reset

Note: This feature is only available when using redundant Supermicro power supplies.

Fan Headers

The X7DBR-3/X7DBR-E has fi ve fan headers, designated Fan1 through Fan5. Fan speed is controlled via Thermal Management with a BIOS setting. See the table on the right for pin defi nitions. (Pins 1-3 on the headers are backward compatible with traditional 3-pin fans.)

Chassis Intrusion

A Chassis Intrusion header is located at JL1. Attach the appropriate cable to inform you of a chassis intrusion.

Fan Header

Pin Definitions

(Fan1-5)

Pin# Defi nition

1Ground (Black)

2 +12V (Red)

3Tachometer

4 PWM Control

Note: Currently only 3-pin control is supported (no PWM).

Chassis Intrusion

Pin Definitions (JL1)

Pin# Defi nition

1Intrusion Input

2 Ground

5-15

Page 49
Image 49
SUPER MICRO Computer 6015B-T, 6015B-3 user manual Serial Ports, Power Supply Fail Header, Fan Headers, Chassis Intrusion