Setup & Use of PEQ

The Level control (labeled “Level:”) determines the amount of cut or boost applied to the frequency re- sponse, centered on the FREQ: frequency and Q: wide. If Level is set to 0, the specific PEQ filter is disabled. Cuts of up to -12 dB and boost of up to +3 dB are allowed.

Below is a frequency response graph of a subwoofer as measured under quasi-anechoic conditions. This set of curves illustrates how the PEQ function works and what type of cut effect you can expect from various Q settings.

Green Line: Native frequency response of the subwoofer.

Purple Line: Frequency = 50 Hz, Q = 14.4, LEVEL = -12 dB

Yellow Line: Frequency = 50 Hz, Q = 2.0 LEVEL = -12 dB

“Q” Control Effects

FIG. 13

© 2011 Specialty Technologies, LLC Call SVSound877.626.5623 www.svsound.com