| Maintenance and Specifications | |
Beeper Indications |
|
| |
|
|
|
|
|
|
|
|
| Standard Use |
|
|
| Beeper Sequence | Indication |
|
|
|
|
|
| Short high tone | A bar code symbol was decoded (if decode beeper is |
|
|
| enabled). |
|
|
|
|
|
| 4 Beeps - long low tone | A transmission error has been detected in a scanned |
|
|
| symbol. The data is ignored. This will occur if a unit is |
|
|
| not properly configured. Check option settings. |
|
|
|
|
|
| 5 Beeps - low tone | Convert or format error |
|
|
|
|
|
| Lo/hi/lo tone | ADF transmit error |
|
|
|
|
|
| Hi/hi/hi/lo tone |
| |
|
|
|
|
| Parameter Menu Scanning |
|
|
|
|
|
|
| Short high tone | Correct entry scanned or correct menu sequence |
|
|
| performed. |
|
|
|
|
|
| Lo/hi tone | Input error, incorrect bar code or “Cancel” scanned, |
|
|
| wrong entry, incorrect bar code programming sequence; |
|
|
| remain in program mode. |
|
|
|
|
|
| Hi/lo tone | Keyboard parameter selected. Enter value using bar code |
|
|
| keypad. |
|
|
|
|
|
| Hi/lo/hi/lo tone | Successful program exit with change in the parameter |
|
|
| setting. |
|
|
|
|
|
| Code 39 Buffering |
|
|
|
|
|
|
| Hi/lo tone | New Code 39 data was entered into the buffer. |
|
|
|
|
|
| 3 Beeps - long high tone | Code 39 buffer is full. |
|
|
|
|
|
| Lo/hi/lo tone | The buffer was erased, or there was an attempt to |
|
|
| transmit an empty buffer. When the Code 39 buffer was |
|
|
| empty, the scanner read a command to clear or to |
|
|
| transmit a Code 39 buffer. |
|
|
|
|
|
| 4 Beeps - long low tone | Error in data transmission. |
|
|
|
|
|
| Lo/hi tone | A successful transmission of buffered data. |
|
|
|
|
|