TANDBERG ENTRYPOINT USER GUIDE
Dial Plan Examples
Given the supported net types, H.324m, H.323 and SIP, 9 unique inbound and outbound net type combinations for both DID and IVR dial plans can be defined
Some of these combinations will be discussed in a few examples.
Example 1: Number-plan mapping
Entry details: | Enabled: | Check |
| Name: | |
| Net Type: | H.324m |
| Prefix: | 6789 |
Suffix: | Service: | Direct Inwards Dialling |
Arguments: | Net Type: | H.323 |
| A V Mode: | Auto + fallback to audio |
| Prefix: | 5 |
Suffix: | Use Remainder: | Yes |
| Allow Forwarding: | No |
When dialling the number 67890000 there will be a match with “0000” as the remaining number. The H.323 number that will be connected to will be: 50000 (construction: Prefix + Use remainder number). When dialling number 67894321 this will match with “4321” as the remaining number. The H.323 number to call will be: 54321. In this way a range of ISDN numbers can be mapped onto for instance a range of H.323 numbers.