TANDBERG IP GW 3500 manual LED behavior, Flashing

Models: IP GW 3500

1 18
Download 18 pages 728 b
Page 6
Image 6
LED behavior

LED behavior

Table 1 describes the behavior of the LEDs.

Table 1: IP GW LED behavior

LED

Color

Indicates

Compact Flash Activity

Flashing

 

green

One of:

the IP GW is booting

a configuration change has been made

the configuration is being transferred by FTP

Console Link

Green

A PC is connected to the console port

 

 

 

Status

Green

The IP GW is operating normally

 

 

 

Alarm

Red

The IP GW is booting or has developed a

 

 

fault, for example:

 

 

temperature is outside normal limits

 

 

fan failure

 

 

battery failure of the internal clock

 

 

Refer to the web interface for more

 

 

information about the problem (go to

 

 

Status > Health)

 

 

 

System Load

Green

The IP GW is processing data. The LEDs

 

 

represent the media processing load of the

 

 

IP GW. The column numbered 1

 

 

represents audio load. The other columns

 

 

represent video DSP load. Media

 

 

processing load is also displayed in the web

 

 

interface: go to Status > General to see

 

 

the percentage load

 

 

 

2

Page 6
Image 6
TANDBERG IP GW 3500 manual LED behavior, Flashing