Factory Defaults
Page E-2 Reference Guide: TT1280 High Definition Professional Receiver/Decoder
ST.RE.E10141.5
Menu Description Default
CLIPPING LEVEL 18 dB
AC3 DOWNMIX METHOD SURROUND STEREO
ASYNC DATA ENABLED
SYNC DATA (High Speed Ethernet Data Not Fitted) ENABLED
ETH.NET DATA (High Speed Ethernet Data Fitted) ENABLED
VITC INSERTION ENABLED
CLOSED CAPTION ENABLED
PCR PID
#5 Output TS OUTPUT POST INPUT
CONNECTOR 1 DISABLED
CONNECTOR 2 DISABLED
#6 Alarm IF NO TRANSPORT STREAM NO ALARM
IF VIDEO NOT RUNNING NO ALARM
IF AUDIO 1 NOT RUNNING NO ALARM
IF AUDIO 2 NOT RUNNING NO ALARM
IF MER LESS THAN 0.00 NO ALARM
IF BER EXCEEDS 1.0 E-8 NO ALARM
IF TEMPERATURE EXCEEDS 65 NO ALARM
#7 Setup OPERATING MODE FRONT PANEL
LCD CONTRAST MEDIUM
SERIAL REMOTE CONTROL RS-232 TTV
IP ADDRESS 155.155.155.201
SUBNET MASK 255.255.255.000
GATEWAY ADDRESS 155.155.155.001
SYSLOG IP ADDRESS NOT SET
SERVICE HUNT MODE ENABLED
SI MODE AUTO
CUSTOMISATION KEY UNAFFECTED
SW VERSION/ FW VERSION/ HW VERSION/
PLD VERSION/ ELECTRONIC SERIAL NUMBER UNAFFECTED