Tandberg Data Installing and Configuring the Tandberg DLT4000 Drive
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
2-14 Tandberg DLT4000 Installation Guide
If Then You should
Your system does
not recognize the
Tandberg DLT4000
tabletop drive
1. The SCSI bus might
be too long.
2. Too many devices
might be on the bus.
1. Limit the bus length to the ANSI
SCSI standard of 6 meters (19
feet) for single ended (SE) or 25
meters (82 feet) for differential.
2. Limit the number of devices on
the bus including the system) to
eight. Check your system
configuration rules.
The Tandberg
DLT4000 tabletop
drive does not
power up
The Tandberg
DLT4000 tabletop
drive has no power
Check the Tandberg DLT4000
power cord connections with the
Tandberg DLT4000 power switch
off.
All right- or all left-
side indicators on
the Tandberg
DLT4000 front
panel blink
A drive fault has
occurred Try to unload the tape and
reinitialize the drive by pressing the
Unload button or turn drive power
off and then on again. The right- or
left-side indicators stop blinking
and the drive tries to reinitialize.
The indicators turn on steady again
and go off if the test succeeds.
You find fatal or
nonfatal errors for
which you cannot
determine he
cause
The bus termination or
SCSI signal cable
connections might be
incorrect
Ensure the SCSI bus is terminated.
The ac power source
grounding might be
incorrect
Use an ac outlet for the Tandberg
DLT4000 tabletop drive on the
same ac line powering the system.