Tandberg Data Configuring and Operating the Tandberg DLT4000 Drive
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
3-14 Tandberg DLT4000 Installation Guide
Label Color State Operating Condition
Indicator (Right front panel)
Write Protected Orange On
Off
Tape is write-protected.
Tape is write-enabled.
Tape in Use Yellow Blinking
On
Tape is moving.
Tape is loaded; ready for use.
Use Cleaning Tape Yellow On Drive head needs cleaning, or
the tape is bad (Section 3.8).
Remains on
after you
unload the
cleaning tape
Cleaning tape attempted to
clean the drive head, but the
tape expired, so cleaning was
not done.
After cleaning,
turns on again
when you
reload the data
cartridge
Problem data cartridge. Try
another cartridge.
Off Cleaning is complete, or
cleaning is unnecessary.
Operate Handle Green On Okay to operate the
cartridge/insert release handle.
Off Do not operate the cartridge
insert/release handle.
Blinking Close handle and wait for a
steady green indication before
inserting cartridge.
All four right-side
indicators or all left-
side indicators
On POST is starting.
Blinking An error has occurred. See
Table 2-4, Tandberg DLT4000
Troubleshooting Chart.

7DEOH'HWHUPLQLQJWKH'ULYHV2SHUDWLQJ&RQGLWLRQ