EXTERNAL CONTROL

Parallel Control

The CD player can be controlled on the parallel interface from external equipment using the REMOTE (PARALLEL) terminal (37-pin D-Sub connector) on the rear panel.

19

1

 

 

37

20

 

Pin Arrangement

 

 

 

Pin No. Signal Name

 

IN/OUT

 

 

 

 

 

1

ON LINE PLAY IN

 

IN

2

MONITOR PLAY IN

 

IN

3

PAUSE IN

 

IN

4

READY IN

 

IN

5

STOP IN

 

IN

6

TRACK SEARCH REV IN [ << ]

 

IN

7

N.C

 

8

TRACK SEARCH FWD IN [ >> ]

 

IN

9

SEARCH REV IN [ << ]

 

IN

10

SEARCH FWD IN [ >> ]

 

IN

11

MONITOR PLAY TALLY

 

OUT

12

READY TALLY

 

OUT

13

PAUSE TALLY

 

OUT

14

STOP TALLY

 

OUT

15

INDEX SERACH REV IN [ <- ]

 

IN

16

INDEX SEARCH FWD IN [ -> ]

 

IN

17

ON LINE PLAY TALLY

 

OUT

18

FLASH READY IN

 

IN

19

FLASH MODE IN

 

IN

20

EOM OUT

 

OUT

21

FADER START/STOP IN

 

IN

22

ONLINE PLAY / MONITOR PLAY OUT

OUT

23

TEN KEY 0 IN

 

IN

24

TEN KEY 1 IN

 

IN

25

TEN KEY 2 IN

 

IN

26

TEN KEY 3 IN

 

IN

27

TEN KEY 4 IN

 

IN

28

TEN KEY 5 IN

 

IN

29

TEN KEY 6 IN

 

IN

30

TEN KEY 7 IN

 

IN

31

TEN KEY 8 IN

 

IN

32

TEN KEY 9 IN

 

IN

33

STOP/READY OUT

 

OUT

34

FLASH READY TALLY

 

OUT

35

FLASH MODE TALLY

 

OUT

36

GND

 

37

+5 V

 

Parallel control I/O specifications

 

 

 

Input

: +5 V pull-up, Low Active, 50 ms or more

 

Output : Open collector, 20 mA max.

 

 

 

+5 V (pin No. 37) max. current: 100 mA

 

 

Setting fader start/stop

Fader start/stop is possible by connecting the No. 21 pin (FADER START/STOP IN) and No. 36 pin (GND) of the REMOTE (PARALLEL) terminal to the external interface. At a fader start, the CD player enters the online playback mode.

To start/stop the CD player from an external fader, set the following menu items.

Setting fader start

Set the polarity using menu No. 14 (“F_STAR”).

NOR (NORMAL): Low Active. The CD player starts when the input signal is switched from High to Low.

REV (REVERSE): High Active. The CD player starts when the input signal is switched from Low to High.

Setting fader stop

Set the state of the CD player at stop operation using menu No. 15 (“F_STOP”).

STP (STOP): The CD player stops.

RDY (READY): The CD player enters the online READY mode.

PUS (PAUSE): The CD player enters the monitor PAUSE mode.

CUE: The CD player returns to the cue point (point at fader start), and enters the online READY mode.

INC (INCREMENT): The CD player enters the online READY mode at the start of the next track.

PLY (PLAY): Online playback is continued.

TASCAM CD-601MKII 25