EXTERNAL CONTROL
Parallel Control
The CD player can be controlled on the parallel interface from external equipment using the REMOTE (PARALLEL) terminal
19 | 1 |
|
| 37 | 20 |
|
Pin Arrangement |
|
| ||
| Pin No. Signal Name |
| IN/OUT | |
|
|
|
| |
| 1 | ON LINE PLAY IN |
| IN |
2 | MONITOR PLAY IN |
| IN | |
3 | PAUSE IN |
| IN | |
4 | READY IN |
| IN | |
5 | STOP IN |
| IN | |
6 | TRACK SEARCH REV IN [ << ] |
| IN | |
7 | N.C |
| – | |
8 | TRACK SEARCH FWD IN [ >> ] |
| IN | |
9 | SEARCH REV IN [ << ] |
| IN | |
10 | SEARCH FWD IN [ >> ] |
| IN | |
11 | MONITOR PLAY TALLY |
| OUT | |
12 | READY TALLY |
| OUT | |
13 | PAUSE TALLY |
| OUT | |
14 | STOP TALLY |
| OUT | |
15 | INDEX SERACH REV IN [ <- ] |
| IN | |
16 | INDEX SEARCH FWD IN [ |
| IN | |
17 | ON LINE PLAY TALLY |
| OUT | |
18 | FLASH READY IN |
| IN | |
19 | FLASH MODE IN |
| IN | |
20 | EOM OUT |
| OUT | |
21 | FADER START/STOP IN |
| IN | |
22 | ONLINE PLAY / MONITOR PLAY OUT | OUT | ||
23 | TEN KEY 0 IN |
| IN | |
24 | TEN KEY 1 IN |
| IN | |
25 | TEN KEY 2 IN |
| IN | |
26 | TEN KEY 3 IN |
| IN | |
27 | TEN KEY 4 IN |
| IN | |
28 | TEN KEY 5 IN |
| IN | |
29 | TEN KEY 6 IN |
| IN | |
30 | TEN KEY 7 IN |
| IN | |
31 | TEN KEY 8 IN |
| IN | |
32 | TEN KEY 9 IN |
| IN | |
33 | STOP/READY OUT |
| OUT | |
34 | FLASH READY TALLY |
| OUT | |
35 | FLASH MODE TALLY |
| OUT | |
36 | GND |
| – | |
37 | +5 V |
| – | |
Parallel control I/O specifications |
|
| ||
| Input | : +5 V | ||
| Output : Open collector, 20 mA max. |
|
| |
| +5 V (pin No. 37) max. current: 100 mA |
|
|
Setting fader start/stop
Fader start/stop is possible by connecting the No. 21 pin (FADER START/STOP IN) and No. 36 pin (GND) of the REMOTE (PARALLEL) terminal to the external interface. At a fader start, the CD player enters the online playback mode.
To start/stop the CD player from an external fader, set the following menu items.
Setting fader start
Set the polarity using menu No. 14 (“F_STAR”).
NOR (NORMAL): Low Active. The CD player starts when the input signal is switched from High to Low.
REV (REVERSE): High Active. The CD player starts when the input signal is switched from Low to High.
Setting fader stop
Set the state of the CD player at stop operation using menu No. 15 (“F_STOP”).
STP (STOP): The CD player stops.
RDY (READY): The CD player enters the online READY mode.
PUS (PAUSE): The CD player enters the monitor PAUSE mode.
CUE: The CD player returns to the cue point (point at fader start), and enters the online READY mode.
INC (INCREMENT): The CD player enters the online READY mode at the start of the next track.
PLY (PLAY): Online playback is continued.
TASCAM