24 Models 750, 751, 754, 774, 791, 794Operating Procedures
101109
Step 5
Install the draw valve(s). Slide the two o- rings intothe
grooves on the draw valve(s), and lubricate.
Figure 12
Note: Models754, 774, 791, and 794 have three draw
valves.
Lubricate the inside of the freezer door spout(s), top
and bottom, and insert the draw valve(s) from the
bottom until the slot in the draw valve(s) comes into
view.
Figure 13
Step 6
Install the adjustable draw handle(s). Slide the o- ring
into the groove on the pivot pin, and lubricate.
Figure 14
Slidethe f ork over the bar in the slot of the draw valve.
Secure with pivot pin.
Figure 15
Note: Models754, 774, 791,and 794 have three draw
handles.Slide the for kof t hedr awhandle in the slot of
the draw valve, starting from the right. Slide the pivot
pin through each draw handle as you insert them into
the draw valves.
Note: These units feature adjustable draw handles to
providethe best portioncontrol. The dr aw handles can
be adjusted for different flow rates. See page 20 for
more information on adjusting these handles.