16 Models 8752 & 8756 with Horizon®PumpImportant:To the Operator
Power Switch
When placed in the ON position, the power switch
allows “SOFTECH” control panel operation.
Indicator Lights --“Mix Low” and “Mix Out”
When the MIX LOW light begins to flash, it indic ates
the mix tank has a low supply of mix and should be
refilled as soon as possible. When the MIX OUT light
begins to flash, it indicates the mix tank has been
almost completely exhausted and has an insufficient
supply of mix to operate the freezer. At this time, the
STANDBY and AUTO modes are locked out and the
freezer shuts down. To initiate the refrigeration
system, addmix to the tank and press the AUTO key.
The freezer will automatically begin operation.
Reset Button
The reset button is located in the decorative plate
above the “SOFTECH” controls. The reset prot ects
the beater motor from an overload condition. Should
an overload occur, the reset mechanism will trip.
Toproperly res et the freezer, press the AUTO key to
cancel the cycle. Turn the power switch to the OFF
position. Press the reset button firmly. Turn the power
switch to the ON position. Press the AUTO key to
resume normal operation. (For the Model 8756, press
the AUTO key on both sides to resume normal
operation.)
WARNING: Do not use metal objects to
press the reset button. Failure to f ollow this
instruction may result in serious el ectrical shock.
If the freezer shuts down again, contact your
authorized service technician.
“Softech” Control OperationMix Ref
Whenthe MIX REF key is pr essed, the light comes on,
indicating the mix cabinet refrigeration system is
operating. (For the Model 8756, there are two
touch--tonepanels, one for each freezing cylinder. The
mix refrigerationsystem is controlled by the MIX REF
keyfound on t he left panel. By pressing the AUTO key
on either side of the freezer, the MIX REF func tion is
automatically turned on.) The MIX REF function
cannot be cancelled unless the AUTO or STANDBY
mode is cancelled first.
Standby
During long “No Sale” periods it becomes necessary
to warm the product in the freezing cylinder to
approximately 35_to 40_F(1.7_to 4.4_C) to prevent
overbeating and product breakdown.
When the STANDBY key is pressed, the light comes
on, indicating the CTR (Cylinder Temperature
Retention System) has been activated. In the
STANDBY mode, the WASH, PUMP, and AUTO
functions are automatically cancelled. The MIX REF
function is automatically locked in to maintain the mix
in the cabinet.
Toresume normal operation, press the STANDBY key
to cancel the cycle, and then press the AUTO key.
When the unit cycles off, the product in the freezing
cylinder will be at serving viscosity.
Wash
When the WASH key is pressed, the light comes on,
indicating beater motor operation. The STANDBY key
orAUTO modes must be cancelled fir st to activate the
WASH mode.