
25
Models 8752 & 8756 with Horizon®Pump Operating Procedures
Step 13
Insert the parts assembledin Step 12 into the valve
outlet fitting.
Figure 37
Step 14
Slide the pressure relief valve onto the main pump
assembly.
Figure 38
Step 15
Secure the pressure relief assembly by installing t he
retaining pin into the rear retaining pin plate.
Figure 39
Note: The assembled p arts must align with the
matchinghole in the mounting plate.
Step 16
Attach one end of the flare line to the pressure relief
valve outlet fitting of the Horizon®pump. Attach the
other end to the mix feed tube.
Figure 40