34 Models 8752 & 8756 with Horizon®PumpOperating Procedures
Step 7
Return to the freezer with a small amount of cleaning
solution. With the blackbristle brush, brush clean the
rear shell bearing(s) at the back of the freezing
cylinder(s).
Figure 64
Step 8
Using the long, flexible brush and the cleaning
solution, clean the mix inlet tube(s) located in the mix
cabinet. Thoroughly clean the tube(s) all the way up to
thefreezing c ylinder.T his area needs special attention
because bacteria and milkstone can build up here.
Figure 65
IMPORTANT:
SDO NOT inserta brush into the pump
tube.
SDO NOT removethe pump tube when
cleaning the unit.
Note: The pump tube is located inside of the
Horizon®pump. (See illustration on page 13.)
Step 9
Removethe rear dr ip pan from the side panel and take
it to the sink for cleaning.
Note: If the rear drip pan is filled wit h an excessive
amount of mix, refer to the Troubleshooting Guide.
Step 10
Thoroughly brush clean all disassembled parts in the
cleaningsolution, making sur e all lubricant and mix film
is removed. Take particular care to brush clean the
draw valve core(s) in the freezer door. Place all the
cleaned parts on a clean dry surface to air dry
overnight.
Step 11
Wipe clean all exterior surfaces of the freezer andthe
mix cabinet.