31
Models 8752 & 8756 with Horizon®Pump Operating Procedures
Draining Product From theFreezing CylinderStep 1
Press the AUTO and MIX REF keys to cancel freezer
operation.
Step 2
Openthe mix cabinet door andremove the mix st orage
cover(s), mix tank cover(s), mix tank(s), and mix
probe(s). Empty the mix from the mix tank(s) into a
sanitized stainless steel rerun can.
Step 3
Place the suction line in an empty pail in the mix
cabinet.
Step 4
If local health codes permit the use of rerun ,place
a sanitized, NSF approved stainless st eel rerun
container beneath the door spout.
SOpen the draw valve and press the WASH
and PUMP keys.
SDrain all the mix from the freezing cylinder.
SWhen all the product stops flowing from the
door spout, close the draw valve and press
the WASHand PUMP keys to stop
operation.
SPlace a sanitized lid on the rerun container
and place it in the walk--incooler.
Note: If local healthcodes DO NOT permit theuse
ofrerun, the product mustbe discarded . Followt he
instructions in the previous step, except drain the
product into a mix pail and properly discard the mix.
Repeat Steps 3 through 4 for the second freezing
cylinder on the Model 8756.
ALWAYSFOLLOW LOCAL HEALTHCODES.
RinsingStep 1
Fillthe em pty pail in the mix cabinet with 2 gallons (7.6
liters) of cool, clean water. Place the free end of the
suction line in the pail of water.
Step 2
Disconnect the pressure line from the check valveand
place it in the pail of water.
Figure 59
Step 3
Press the PUMP key. This action will cause the rinse
water to be pumped through the Horizon®pump and
out through the pressure line. After approximately 15
seconds, press the PUMP key to stop operation.
Step 4
Drain and connect the free end of the pressure line to
the check valve.
Figure 60