30 Models 8752 & 8756 with Horizon®PumpOperating Procedures
Step 7
Press the PUMP key. This will allow the mix to be
pumped through the freezing cylinder and force out
any remaining sanitizer. When full strength mix is
flowing from the door spout, close the draw valve.
Figure 56
Step 8
Whena steadys tream of mix is flowing fr om the prime
plug hole in the bottom of the freezer door, press the
PUMP key to stop operation.
Step 9
Once the stream of mix stops flowing from the prime
plug hole, push the prime plug down. Rinse the prime
plughole area with water. Remove the pail and discard
the mix and the sanitizer.
Figure 57
Step 10
Press the AUTO key. The MIX REF light will come on
indicatingthe mix refrigerat ion system is operating, the
AUTO light will come on indicating the main
refrigeration system is operating, and the PUMP light
willcome on indicating the Horizon®pum p will operate
whenever mix is needed in the freezing cylinder.
Figure 58
Repeat Steps 1 through 8 for the other side of the
freezer on the Model 8756.
When the unit cycles off, the product will be at the
correct viscosity.
Note: Keept he mix cabinet door closed except when
filling the mix tank and during the cleaning and
sanitizing procedures. Leaving the door open with the
mixrefrigerat ion system on may cause the evaporator
to ice up and impair the mix cabinet refrigeration.
Closing ProcedureTo disassemble the Models 8752 and 8756, the
following items will be needed:
STwo cleaning and sanitizing pails
SSanitized stainless steel rerun can with lid
SNecessary brushes (provided with freezer)
SCleaner
SSingle service towels