Technicolor - Thomson CDP-CX57 0.02, 1Err*01, Aging procedure, Error Display, Error code

Models: CDP-CX57

1 58
Download 58 pages 60.78 Kb
Page 13
Image 13
0.02

*3 Aging cycle count function:

Functions which displays the number of agings carried out on

the Fluorescent indicator tube

in numbers. One aging cycle

consists of six discs.

 

Aging carried

 

(Hexadecimal)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 DISCS

CD1

 

 

1

 

SEC

 

 

 

 

DISC

MIN

 

 

 

 

 

 

TRACK

 

 

 

 

 

 

 

51

 

 

 

1

 

0.02

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Disc number

Track number

 

 

 

 

 

Aging procedure:

Some operating method will be changed depending on if the fol- lowing jig for the aging mode exists or not.

• Jig

 

 

 

Parts. No

 

Description

 

 

J-2501-123-A

Remote commander (For aging mode)

Error Display

1 DISCS

1

 

 

 

 

CD1

 

 

 

DISC

 

 

 

 

 

 

40

 

1Err*01

 

 

 

 

 

 

 

 

 

 

 

Disc

 

number

Error

 

code

 

 

Without remote commander for aging mode:

1.Turn ON the power of the unit. Open the front cover.

2.Press the [PLAYÊMODE], á , and - buttons in order.

3.When the disc set mode is set, the á and P LEDs blink.

The following procedure is the same as in the case “With remote commander for aging mode”.

With remote commander for aging mode:

1.Turn ON the power of the unit. Open the front cover.

2.Press the [AGINGÊSTART] button of the remote commander for aging mode.

3.When the disc set mode is set, the á and P LEDs blink.

4.Rotate the JOG dial. The slits (No. 10, 20, 30, 40, 51) for setting the discs will come forward. Insert the discs into these slits. Do not set the discs in other slits.

5.Set the use/disuse of the self protection function in errors. Press the [REPEAT] button. When REPEAT is displayed on the fluo- rescent indicator tube, the self protection function during the error will become “Use”.

If the REPEAT display is OFF, it means that the function is not used. (Normally set to “Use” when performing aging.)

6.Press the á button.

7.The á LED blinks, the aging mode is set, and aging is started.

8.The aging cycle lasts 3 minutes. When problems occur during aging, the error number will be displayed on the fluorescent in- dicator tube, and the P LED will light up.

(Refer to the following table for the details of the errors.)

9.Aging will be repeated as long as no errors occur.

10.After each aging cycle, the number displayed on the Fluores- cent indicator tube will increase.

11.To end aging, press the I/u button

Error code

 

Code number

 

Name

Contents

 

 

 

 

 

 

 

Err 01

DISC sensor check 1

No disc in the specified slit

 

 

 

 

 

 

 

Err 02

DISC sensor check 2

Disc in other slits

 

 

 

 

 

 

 

Err 03

 

 

 

No function

 

 

 

 

 

 

 

 

 

 

 

Err 04

Table operation check 2

No table sensor input

 

 

 

 

 

 

 

Err 05

Loading operation check 1

Load in timeover

 

 

 

 

 

 

 

Err 06

Loading operation check 2

Load out timeover

 

 

 

 

 

 

 

Err *1

BU related check 1

Access timeover

 

 

 

 

 

 

 

Err *2

BU related check 2

High speed search NG

 

 

 

 

 

 

 

Err *3

BU related check 3

Q data read error

 

 

 

 

 

 

 

Err *4

BU related check 4

BU operation (From focus search to until signal can be read) timeover

 

 

 

 

 

 

 

Err *5

BU related check 5

GFS monitor error

 

 

 

 

 

 

 

Err *6

BU related check 6

Focus cannot be imposed by focus search

 

 

 

 

 

 

The * numbers mean the following according to the state of the unit during aging 2 : From checking to end of TOC read

3 : From end of TOC read to end of last track playback

4 : From end of last track playback to end of first track playback

– 13 –