Rinsing the boiler  (once a month)

1800112827 GV51XX 14/01/08 15:10 Page 21

Rinsing the boiler Is there any problem (once a month)

If your water is hard, increase the frequency. In particular, do not use descaling agents for rinsing out the boiler, as they could damage it.

• Be careful : To extend the life of your boiler and to avoid the building up of scale, it is

 

essential that you rinse out the boiler at least after every 10 uses (H) (approximately once

 

a month).

 

• Check that the generator is cold and unplugged for more than 2 hours.

 

• Using a jug, fill the boiler 3/4 full with untreated tap water.

 

• Shake the base unit for a few moments and then empty it completely over your sink (I).

GB

• To obtain the best results, we advise you to repeat this operation.

 

Is there any problem

Problems

Possible causes

Solutions

 

 

 

Water runs through the holes in the

The boiler is too full.

Do not fill the boiler right up to the top.

sole plate.

The thermostat is not working : the

Contact an Approved Service Centre.

 

temperature is always too low.

 

 

You are using the steam control button

Check the thermostat and steam flow

 

before the iron is hot enough.

settings (according to model).

 

Water has condensed in the pipes because

Press the steam control button away from

 

you are using steam for the first time or you

your ironing board until the iron produces

 

have not used it for some time.

steam.

 

 

 

White steaks come through the holes

Your boiler has a build-up of scale because

Rinse the boiler every 10 uses (see § rinsing

in the soleplate.

it is not rinsed out regularly.

the boiler). If your water is hard, increase

 

 

the frequency.

Brown streaks come through the holes in

You are using chemical descaling agents or

Never add this type of product in the boiler

the soleplate and stain the linen.

additives in the water for ironing.

(see § what water to use).

 

Your linen is not rinsed sufficiently or you

 

 

have ironed a new garment before washing

Ensure linen is rinsed thoroughly to remove

 

it.

any soap deposits or chemicals on new

 

 

garments which have been sucked up by

 

 

the iron.

The soleplate is dirty or brown and may

You are ironing at too high a temperature.

See our recommendations regarding

stain the linen.

 

temperature control setting.

 

You are using starch.

Always spray starch on the reverse side of

 

 

the fabric to be ironed.

There is no steam.

The boiler is empty.

Fill the boiler.

 

The boiler is not yet ready.

After starting the appliance, wait for 8 mins

 

 

or until the steam ready indicator light

 

 

comes on (according to model).

 

 

 

Steam escapes from the boiler cap.

Cap screwed on incorrectly.

Screw the cap back on.

 

The seal on the cap is damaged.

Contact an Approved Service Centre.

 

The appliance is faulty.

Stop using the generator and contact an

 

 

Approved Service Centre.

Steam or water escape under the

The appliance is faulty.

Stop using the generator and contact an

appliance.

 

Approved Service Centre.

If you have any product problems or queries please contact our Customer Relations Team first for expert help and advice:

HELPLINE: 0845 602 1454 - UK (01) 461 0390 - Ireland or consult our website - www.tefal.co.uk

Environment protection first !

Problems Your appliance contains valuable materials which can be recovered or recycled.

￿Leave it at a local civic waste disposal centre.