•The colour of the bowl surface may change after using for the first time or after longer use. This change in colour is due to the action of steam and water and does not have any effect on the use of the Rice Cooker, nor is it dangerous for your health. It is perfectly safe to continue using it.
Cleaning and care of the other parts of the appliance
•Unplug the appliance before cleaning.
•Clean the outside of the Rice Cooker, the inside of the lid – Fig.24 and the cord with a damp cloth and wipe dry. Do not use abrasive products.
•Do not use water to clean the interior of the appliance body as it could damage the heat sensor.
Technical troubleshooting guide
Malfunction description | Causes | Solution | |
|
|
| |
Any indicator lamp off and no | Rice cooker not plugged. | Verify the main plug is well | |
heating. | engaged in the product body. | ||
| |||
|
|
| |
Any Indicator lamp off and | Problem of The connection of | Send to authorized service | |
the indicator lamp or Indicator | |||
heating. | center for repair. | ||
lamp is damaged. | |||
|
| ||
|
|
| |
Cooking Indicator lamp off, | Cook button is not in cooking | Put the cook button in low | |
keep warm indicator on. | position. | position (cooking). | |
|
|
| |
| Lid is badly closed. | Open and close again the lid. | |
|
|
| |
|
| Stop the cooking (unplug the | |
Steam leakage during using. | Micropressure valve not well | product) and check the valve is | |
positioned or uncomplete. | complete (2 parts locked | ||
|
| together) and well positioned. | |
|
|
| |
| Lid or micropressure valve | Send to authorized service | |
| gasket is damaged. | center for repair. | |
|
|
| |
Rice half cooked or overtime | Too much or not enough water | Refer to IFU for water quantity. | |
cooking. | compared to rice quantity. |
| |
|
|
| |
Rice half cooked or overtime | Not sufficiently simmered. | Simmer as required in IFU | |
cooking. | cooking paragraph. | ||
| |||
|
|
| |
Automatic |
| Send to authorized service | |
(product stay in cooking |
| ||
| center for repair. | ||
position, or no heating). |
| ||
|
| ||
|
|
| |
Water leakage on the table. | Dew collector missing or dew | Empty the dew collector for each | |
use verify good positionning of | |||
collector overflow. | |||
| the dew collector. | ||
|
| ||
|
|
|
Remark : if inner bowl is deformed, do not use it anymore and get a replacement bowl from the authorized service center for repair.