44
(Rev.8/04)
®
VI. Configuration Procedures
The Setup option on the main menu gives the user the ability to vary
some aspects of the system configuration. Some of these require the
entry of a passcode to prevent unauthorized access.
Note: Those functions which are denoted as System Functions apply to the entire
C-2000 system and can be programmed from any single MagnaStar handset.
A. Station Configuration at a GlanceThe user can access these menus by taking the handset off-hook,
pressing “9”(Setup) -“3”(Info), and then continue to press the “+”
key to select each successive menu.
(Factory Default)
“Station Setup”‘Cabin’
“Ringer”‘Enabled’
“Call Waiting is ‘Enabled’-or- ‘Disabled’” ‘Enabled’
“Direct Call Pick-up is ‘Enabled’-or- ‘Disabled’” ‘Enabled’
“Aircraft Number Alerting is ‘Enabled’-or- ‘Disabled’” ‘Enabled’
“Auto Link Switch is ‘Enabled’-or- ‘Disabled’” ‘Enabled’
“Station Default Baud Rate”9600 bps
“Modem Call Handoff is ‘Enabled -or- ‘Disabled’” 4800 bps ‘Disabled’
9600 bps ‘Enabled’
“OCXO Cal. Factor:+/- xxx Hz”(current OCXO Calibration Factor)
“RSS:- xxxdB”(Current Receive Signal Strength of Ground Station)
“ARTU Serial Number”(Assigned serial number “MSA-xxxx”)
“Elapsed Time Indicator”(Current elapsed powered up time in minutes)
NOTE 1: The Factory defaults listed above are applied to software version 4.0A
and later.
NOTE 2: While in Remote Program mode for the CDBR-2, the station type (i.e.
Voice,Fax, Modem or PC) is displayed, as well as the CDBR’s software
version.
NOTE 3: The features that are disabled by default (see Factory Default above) must
be enabled by an Installer who has access to the Maintenance Passcode.