2L. Start-up and Adjustment

Hi-E2

Page 13

 

IMPORTANT: If an automatic chlorinator is

Method For Installing

being used, equip the chlorinator with an anti-

Any Threaded Pipe

siphoning device so that chlorine will not siphon into

 

the heater after the pump shuts off.

 

Wire an electric chlorinator so that it cannot

 

operate unless the filter pump is running. If the

 

chlorinator has an independent clock control,

 

synchronize it with the filter clock.

 

If the chlorinator is equipped with its own pump,

Use

install it so that it introduces the chlorine downstream

Plastic

from the heater, and, if possible, below the level of the

Sleeve

heater outlet fitting.

 

2L. Start-up and Adjustment

For Nonthreaded Pipe

2L-1. Normal Operation

The Hi-E2pool heater operates automatically. It

or Tube, Discard

provides heat in response to the selector switch and

Plastic Sleeve

 

temperature settings on the FlexTemp control panel on

 

the front of the heater. The heater has internal controls

 

to sense adequate water flow and to handle any

 

abnormal condition.

 

Normal operation is as follows:

 

1. The pool/spa system filter pump provides

 

water flow. A pressure-flow switch in the

 

heater detects water flow and enables the

Figure 21. Piping to Heater.

FlexTemp control to operate the heater. (If

the recommended fireman switch has been

 

 

provided, it must also enable operation.)

Out

Water

In

Figure 22. Pressure Relief Valve Installation.

2.If the FlexTemp selector switch is set to "Pool" or "Spa", and if the water temperature is not warm enough, the FlexTemp control signals the combustion system to start.

3.The ignition control starts the combustion blower.

4.When the venturi pressure switch detects combustion air flow and when a suitable “pre-purge” time has been allowed, the ignition control energizes a “hot surface” igniter.

5.The igniter is allowed to reach ignition temperature, at which it glows bright red- orange. This is visible through the combustion chamber view port.

6.The gas valve is opened and gas flows into the combustion air. The gas/air mixture flows through the burner into the combustion chamber. It is ignited by the igniter.

7.The ignition control electronically senses successful ignition by “flame rectification”, and the gas valve is allowed to stay on. The igniter is de-energized.

8.The heater operates for as long as the FlexTemp control demands heat, subject to