Page 1 | |
|
|
|
|
SECTION 1.
General Information
1A. Introduction
This manual contains information for the proper installation and operation of the
1B. Description
The
The heater is designed to operate in conventional swimming pool and spa equipment arrangements. It requires 115V 60 Hz electrical power. It has the versatile Teledyne Laars FlexTemp
The
The heater has been designed specifically to heat fresh water swimming pools and spas, and with proper installation and care, it will provide years of reliable service. Do not use it to maintain pool or spa water temperature below 70°F. Do not use it as a heating boiler or general service water heater or to heat salt water. For special applications, consult your Teledyne Laars dealer.
1C. Warranty
The
WARNING
Improper installation or servicing can cause property damage, injury or death due to fire, asphyxiation or carbon monoxide poisoning.
SECTION 2.
Installation Instructions
2A. General Requirements
All
1.Appropriate site location and clearances.
2.Sufficient supply of clean air for combustion and ventilation.
3.Proper venting of products of combustion.
4.Properly sized gas pipe.
5.Properly sized gas meter.
6.Adequate water flow.
7.Provision for disposal of combustion condensate water.
In the United States, installation must be in accordance with local codes and the most recent edition of the National Fuel Gas Code, ANSI Z223.1. The Code can be obtained from:
National Fire Protection Association 1 Batterymarch Park
Quincy, MA 02269
In Canada, install the heater in accordance with local codes and the most recent edition of the Installation Codes for Gas Burning Appliances, CAN
Canadian Gas Association 55 Scarsdale Road
Don Mills, Ontario M3B 2R3
Special Precautions
Liquefied petroleum (LP) gas is heavier than air. Therefore, a pool heater using LP gas is subject to special installation rules. Consult local codes and fire protection authorities about specific installation restrictions.
Fuel gas and its combustion products are known to cause cancer or harm the reproductive process. Follow these installation instructions and applicable codes exactly to avoid this.