Manuals
/
Teledyne
/
Computer Equipment
/
Computer Monitor
Teledyne
PEM 9002 Chestnut Street City of Industry, California 91748, USA TEL, Toll Free Fax
Models:
PEM 9002
1
2
49
49
Download
49 pages
50.86 Kb
1
2
3
4
5
6
7
8
<
>
Warranty
Maintenance
Configuration Menu
Reset
b Measuring Procedure
Battery / Line Voltage Operation
Waste Gas Cleaning System
Combustion Air or Ambient Temperature Measurement
CO2 = CO2max * 1 - ------- in % Volume
Page 2
Image 2
16830 Chestnut Street City of Industry, California 91748, USA
TEL:
626-934-1500
TOLL FREE:
888-789-8168
FAX:
626-934-1651
www.teledyne-ai.com
Page 1
Page 3
Page 2
Image 2
Page 1
Page 3
Contents
Portable Emissions Monitor
US - Version
16830 Chestnut Street City of Industry, California 91748, USA TEL
TOLL FREE FAX
Page
WARRANTY SUMMARY
Page
Table of Contents
1. Product Description
b Measuring Procedure
c Instrument Description
2. Physical Data
+ 32 F to + 1.850 F 0 C ... + 1.000 C
20.9
CO2 = CO2max * 1 - ------- in % Volume
2.1 Calculation Formulae
qA = T.Gas - T.Air * ---------- + B in %
Draft or Pressure Measurement
Technical Data
Combustion Air or Ambient Temperature Measurement
Carbon monoxide CO Measurement with H2 compensation
Oxygen O2 Measurement
Carbon dioxide CO2 Calculation
± 5 % of reading up to 4.000 ppm
CO Measurement without H2 compensation
Options
Nitrogen monoxide NO Measurement
Sulphur dioxide SO2 Measurement
4 Front Panel Overview
TELEDYNE
Start Measurements
5 Keypad Functions
On / Off
Fuel Selection Scroll Key
START STOP S1 S2
6 User Guide
6.1 Program Start Menu
6.2 Calibration Menu
Batt
6.3 Fuel Selection
Natural Gas
START
6.4 Additional Functions of the Measuring Program
Gas Feed Pump
STOP
6.5 Draft Measurement
No pressure values Exceeding ± 60 inches of H2O ± 150 hPa mbar
Unit
6.6 Menu Lines
Graphic
Hold
Zoom
20.9
6.6.1 Menu Line
Info
please contact the supplier
6.6.1.1 Menu Information Box
If the failure or degrading keeps occuring and cannot be fixed
Return
Edit.date
6.6.1.2 Menu Time and Date
Info
Sensor
6.6.2.1 Menu Graphic
6.6.2 Menu Line
From the measuring program
Graphic
CO-Protect
6.6.2.2 Menu Core of waste gas flow Max. Draft
6.6.2.3 Menu CO Purge System manual
6.6.3.2 Menu O2 - Reference
6.6.3 Menu Line
6.6.3.1 Menu Units
Unit
Terminate editing function
6.6.3.3 Menu Additional Data add. Data
Advance to the next digit position
Return
Memory Calls up the memory program
6.6.4 Menu Line
6.6.4.1 Memory Functions
Case
Case 1 No memory blocks created
Create new memory block
Stores measured values in the selected block
Memory
Case 2 Memory blocks already exist
Save
Graphics display of measured values
Other Memory Functions
Views selected memory blocks
Prints the stored measurement
6.6.4.2 Menu Create Memory Blocks
ABCabc
Select
Selects the next entry line
Returns to the measuring menu
Return
6.6.4.3 Menu Delete Memory Data
Return
Delete all
Attention All memories inlcuding additional data will be deleted
Delete all Clears all memories
Deletes all
Deletes measurements only
Printout of current measuring values
Hold
6.6.4.4 Printing the Measured Values
Intermediate storage of measured values
Changing the Configuration Data
6.7 Configuration Menu
Call up the Configuration Menu
Switches the acoustic signal On / Off
Confirm Reset
Reset
Resets all instrument parameters
Auto-off Illumination Reset
6.8 Entering the Company Address
Empty the condensate reservoir completely after each measuring
7. System Maintenance
See drawing on page
pumps and sensors
Status display of the
9. Battery / Line Voltage Operation
8. RS - 232 Interface
Information on Charging the Battery
Used or Dead Battery
Printer Ribbon Paper
Loading Paper
2 x Screw M3x6 Printer Compartment Door
dry filtrate
11. Waste Gas Cleaning System
fine filter
water trap
If the pump capacity decreases, change the hydrophob filter
11.1 PEM 9002 - Filters and other cleaner parts
Check the microfilter for contaminations and change as necessary