Texas Instruments TPA6110A2 MSOP manual Quick Start List for Stand-Alone, Operation

Models: TPA6110A2 MSOP

1 18
Download 18 pages 49.8 Kb
Page 14
Image 14
2.3 Quick Start List for Stand-Alone

Quick Start List for Stand-Alone

2.3 Quick Start List for Stand-Alone

Follow these steps to use the TPA6110A2 MSOP EVM stand-alone or when connecting it to existing circuits or equipment. Connections to the TPA6110A2 MSOP module header pins can be made via individual sockets, wire-wrapping, or soldering to the pins, either on the top or the bottom of the module circuit board. Numbered callouts for selected steps are shown in Figure 2±2 and details appear in Chapter 3.

Figure 2±2. Quick Start Module Map

 

 

 

 

 

2

 

 

Shutdown

 

VDD

GND

 

5

 

 

S1

 

C5

 

 

 

 

 

 

 

4

IN1

R1

C3

R2

 

 

GND

 

 

 

 

 

 

 

 

R5

 

 

C1

 

 

Vo1

 

 

 

 

 

 

U1

 

 

 

GND

 

 

 

 

C4

 

 

 

 

 

 

 

 

 

C2

R3

R4

 

 

 

 

 

TEXAS

 

 

 

 

INSTRUMENTS

GND

4

IN2

 

SLOP338

 

Vo2

GND

TPA6110A2 MSOP EVM

 

 

 

6

6

²Due to the very small size of the MSOP IC package, the standard part number TPA6110A2 is replaced with the code TIAIZ.

-Power supply

1)Ensure that all external power sources are set to off.

2)Connect an external regulated power supply set to 5 V to the module VDD and GND pins, taking care to observe marked polarity.

-Inputs and outputs

3)Ensure that the signal source level is set to minimum.

4)Connect the audio source to the module IN1, IN2, and GND pins, taking care to observe marked polarity.

5)Connect the shutdown (S1) pin to VDD through a normally open switch.

6)Connect 32-Ωheadphones to the module VO1, and VO2 pins through 33 F to 1000 F output-coupling capacitors (see Figure 2±3) and return to the GND pin, or

7)For line output, connections to the VO1 and VO2 pins must be made through 33 F to 1000 F output-coupling capacitors and returned to GND.

-Power-up

8)Verify correct voltage and input polarity and set the external power supply to ON.

The EVM should begin operation.

9) Adjust the signal source level as needed.

2-4

Operation

Page 14
Image 14
Texas Instruments TPA6110A2 MSOP manual Quick Start List for Stand-Alone, Operation