Thermador PH54 Installing an Integral Blower VTN1030C, Install blower in hood, Blower preparation

Models: PH30 PH36 PH42 PH48 PH54

1 38
Download 38 pages 27.06 Kb
Page 10
Image 10
Installing an Integral Blower VTN1030C

Installing an Integral Blower VTN1030C

The hood can be installed with a

VTN1030C blower.

Install blower in hood:

1.The blower is attached to the hood using weld studs provided on the mounting plate.

Blower preparation

Shipping brackets

Wire tie

Capacitor

Blower Front View

Figure 12a

1.Remove left and right shipping brackets and discard.

2.Cut wire tie shown in Figure 12a. Locate the wire harness with the Molex 6-pin connector. Route wire harness out rear of blower, as shown in Figure 12b. below.

3.Re-attach wire harnesses to capacitor with new wire tie (supplied) in same location in front.

Add wire tie here

Wire

Harness

Blower Rear View

2.Figure 12c shows the weld studs in location B for horizontal (rear) discharge. Attach four #10- 24 nuts to the weld studs. For vertical discharge, attach nuts to studs at the top of the mounting plate.

Figure 12c

3.Guide the motor mounting plate over the nuts and tighten to secure the blower to the hood.

4.Attach two (2) additional screws as shown in Figure 12d.

Ventilator

Assembly

Additional

Screws

Figure 12b

Figure 12d

4.Attach wire harness with Molex 6-pin connector to housing as shown in Figure 12b with wire tie (supplied).

The hood can be installed with a CAUTION:

Verify that the two (2) additional screws in Figure 12d are installed and properly tightened before continuing.