Thermador PRDS36, PRG304 GAS and Electric Supply Zones, Grounding plug. IT Must be Plugged, Model

Models: PRDS304 PRDS48 PRG304 PRDS36

1 28
Download 28 pages 62.99 Kb
Page 8
Image 8

STEP 2: CABINET PREPARATION

GAS AND ELECTRIC SUPPLY ZONES:

FIG. 3a

Gas & Electrical Supply Zone for PRG304, PRG36 & PRG48 All-Gas Ranges

Typical placement shown.

Three-Prong,

Other placement of Gas

120 VAC

 

Supply and Electrical

Receptacle

 

Receptacle within the

 

Electrical and Gas Supply

 

Zone is acceptable.

 

NOTE:

 

A Manual Gas

 

Shut-Off Valve

 

(not shown) must

 

be easily accessible

 

through an adjacent

1 3/4" Maximum

cabinet without moving

Protrusion from Wall

the range.

for Gas Supply

 

5/8" Flex Line to

The All-Gas Ranges are factory equipped

Appliance

with a power supply cord with a three-prong

 

 

grounding plug. IT MUST BE PLUGGED

Gas & Electrical INTO A MATING, GROUNDING-TYPE. 120 Supply Zone VAC RECEPTACLE THAT IS CON-

1/2" N P T NECTED TO A CORRECTLY POLARIZED AND GROUNDED 120 VAC CIRCUIT. (See STEP 6.)

The range must beconnected only to the type of gas for which it is certified.

If the range is to be connected to propane gas, ensure that the propane gas supply tank is equipped with its own high pressure regulator in addition to the pressure regulator supplied with the range. (See STEP 5.)

FIG 3b Gas & Electrical Supply Zone for PRDS304 Dual-Fuel Ranges

Typical placement shown. Other placement of Gas Supply and Electrical Receptacle within the Electrical and Gas Supply Zone is acceptable.

NOTE:

A Manual Gas Shut-Off Valve (not shown) must be easily accessible

through an

2" Maximum Protru

adjacent cabinet without sion from Wall for Gas

movingSupply the range.

5/8" Flex Line to Appliance

1/2" N.P.T.

240 VAC Receptacle

(Shown) or Junction

Box

Gas &

Electrical •^Supply Zone

4-3/4"

The Dual-Fuel ranges may be connected to the power supply with a 3-pole, 3- conductor range supply cord kit, a 3-pole, 4-conductor range supply cord kit or by hard-wiring to the power supply. It is the responsibility of the installer to provide the proper wiring components (cord or conduit and wires) and complete the electrical connection as dictated by local codes and ordinances, and/or the National Electric Code. The units must be properly grounded. Refer to Step 6 for details.

The range must be connected only to the type of gas for which it is certified. If the range is to be connected to propane gas, ensure that the propane gas supply tank is equipped with its own high pressure regulator in addition to the pressure regulator supplied with the range. (See STEP 5.)

FIG. 3c Gas & Electrical Supply Zone for PRDS36 and PRDS 48 Dual-Fuel Ranges

Typical placement shown. Other placement of Gas Supply and Electrical Receptacle within the Electrical and Gas Supply Zone is acceptable.

NOTE:

A Manual Gas Shut-Off Valve (not shown) must be easily accessible

through an

2" Maximum

adjacent cabinet without

Protrusion from Wall

moving

for Gas Supply

the range.

 

Model

B

PRDS36 7"

PRDS48 12" 16"

5/8" Flex Line to Appliance

240 VAC Receptacle

(Shown) or Junction

Box Electrical

Supply Zone

The Dual-Fuel ranges may be connected to the power supply with a 3-pole, 3- conductor range supply cord kit, a 3-pole.

4-conductor range supply cord kit or by hard-wiring to the power supply. It is the responsibility of the installer to provide the proper wiring components (cord or conduit and wires) and complete the electrical connection as dictated by local codes and ordinances, and/or the National Electric Code. The units must be properly grounded. Refer to Step 6 for details.

The range must be connected only to the type of gas for which it is certified. If the range is to be connected to propane gas, ensure that the propane gas supply tank is equipped with its own high pressure regulator in addition to the pressure regulator supplied with the range. (See STEP 5.)

Page 6

Page 8
Image 8
Thermador PRDS36, PRG304, PRDS48, PRDS304 GAS and Electric Supply Zones, Grounding plug. IT Must be Plugged, Model