Thermador UCV36 in inches, UCV30/36/45 INSTALLATION DIMENSIONS WITH THERMADOR COOKTOPS, SGS304

Models: 98 Cooktop UCV36 UCV30 UCV45 UNIVERSAL COOK'N'VENT

1 16
Download 16 pages 2.19 Kb
Page 9
Image 9
TABLE 3 (in inches)

TABLE 3 (in inches)

UCV30/36/45 INSTALLATION DIMENSIONS WITH THERMADOR COOKTOPS

Cooktop Model No.

CW

Cutout

Width

CD

Cutout

Depth

OW

Overall

Width

OD

Overall

Depth

SB

Minimum

Set Back

BT, Max++

Backsplash

Thickness

30” Cooktops: Installed with UCV30

SGS304*

SGSX304*

CET304

CEP304

CEM304

28-15/16

28-15/16

28-3/4

28-3/4

28-3/4

22-1/4

22-1/4

22-1/8

22-1/8

22-1/8

31

31

31

31

31

23-3/4

23-3/4

23-7/8

23-7/8

23-7/8

1-1/2

1-1/2

2-1/2

2-1/2

2-1/2

3/4

3/4

0

0

0

36”Cooktops: Installed with UCV36

SGS365**

SGSX365**

CET365

CEP365

CEM365

34-15/16

34-15/16

34-3/4

34-3/4

34-3/4

22-1/4

22-1/4

22-1/8

22-1/8

22-1/8

37

37

37

37

37

23-3/4

23-3/4

23-7/8

23-7/8

23-7/8

1-1/2

1-1/2

2-1/2

2-1/2

2-1/2

3/4

3/4

0

0

0

45” Cooktops: Installed with UCV45

SGS456

SGSX456

CET456

CEP456

CEM456

43-15/16

43-15/16

43-3/4

43-3/4

43-3/4

22-1/4

22-1/4

22-1/8

22-1/8

22-1/8

46

46

46

46

46

23-3/4

23-3/4

23-7/8

23-7/8

23-7/8

1-1/2

1-1/2

2-1/2

2-1/2

2-1/2

3/4

3/4

0

0

0

Table 3 Notes

 

 

 

 

 

 

 

 

 

All dimensions are in inches and are based upon a

*

Dimension "SB" is the minimum distance from the leading

standard 24" deep base cabinet

with

25"

 

edge of the

counter

to

the leading

edge of the cutout.

 

countertop.

 

 

+ +

Dimension

"BT" is

the

thickness

 

of back-splash

that

 

 

 

* * SGC and SGCS cooktops are 1" wider

at center of

 

provides

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

cooktop than shown in chart above.

 

 

 

1/8" clearance

between

vent and

backsplash.

Any

 

 

 

Refer to cooktop Installation Instructions for complete

 

backsplash

with

a curved

radius

where it

meets

the

 

information prior to making any cutouts.

 

 

 

counter will require additional

clearance.

Thicker

 

 

 

Clearance is provided to allow raising of the hinged main

 

backsplashes

may be

used

by increasing the counter

and

 

top .

 

 

cabinet depths.

Figure 7

INSTALLATION WITH THERMADOR COOKTOPS WHEN SPECIFIED

(SEE PART B)

 

 

 

 

-

UCV45

 

 

 

 

 

UCV36

43

 

 

 

 

-

 

UCV30

-1/2"

 

 

-

 

 

-1/2"

 

 

 

 

 

 

 

 

 

34

 

-1/2"

 

 

28

 

 

 

 

 

 

 

 

 

 

1/8" UCV30/36/45 INSTALLATION DIMENSIONS WITH THERMADOR COOKTOPS30” Cooktops: Installed with UCV30

BT

CD

OD

 

SB

2-1/4"

W SGS304*C OW

Page 8

Page 9
Image 9
Thermador UCV36, 98 in inches, UCV30/36/45 INSTALLATION DIMENSIONS WITH THERMADOR COOKTOPS, See Part B, SGS304, 28-15/16