2 STAGE FIRING RATES
CAPACITY | FIRING | NOZZLE SIZE | INPUT RATE* | EFFECTIVE** | |
| RATE | Riello | (BTU/HR) | HEATING | |
|
|
|
| CAPACITY | |
HIGH CAPACITY | HIGH FIRE | .70 X 45° W | 106,250/170psi | 90,000 | |
LOW FIRE | 85,000/130psi | 74,000 | |||
|
| ||||
LOW CAPACITY | HIGH FIRE | .50 X 45° W | 85,000/170psi | 74,000 | |
LOW FIRE | 70,000/130psi | 60,000 | |||
|
|
Table 9: Riello
*Based on #2 domestic heating fuel oil having heating value of 140,000 BTU per gallon.
**Based on thermal efficiency of
MOUNTING THE 2-STAGE RIELLO BURNER:
It is necessary that the insulation gasket be placed between the mounting plate and the burner flange. The insulating gasket has six holes, which, if necessary, can be modified as shown. (see figure
Figure | Figure |
Verify that the installed burner is lightly leaned towards the button. (See figure