Thermo Products omd-70 service manual a. Combustible material

Models: omd-70

1 49
Download 49 pages 20.13 Kb
Page 8
Image 8
a. Combustible material:

All installations and services must be performed by qualified service personnel.

II.GENERAL INSTRUCTIONS AND CLEARANCES NOTE: READ THIS SECTION BEFORE STARTING INSTALLATION

1.The selection of a furnace heating capacity for a proposed installation should be based on a heat loss calculation made according to the manuals provided by the Air Conditioning Contractors of America (ACCA) or the American Society of Heating, Refrigeration and Air Conditioning Engineers, Inc. (ASHRAE).

2.The installer shall be familiar with and comply with all codes and regulations applicable to the installation of this heating appliance. In addition to the governing standards items a) through e) this appliance shall also comply with “CSA B139 for recommended installation practices” where applicable.

a.Federal Manufactured Home Constructions & Safety Standard (HUD Total 24, Part 280).

b.American National Standard (ANSI-119.2/NFPA-501C), for all recreational vehicle installations.

c.American National Standard (ANSI-Z223.1/NFPA-54), for all gas-fired furnaces.

d.American National Standard (ANSI-Z95.1/NFPA-31), for all oil-fired furnaces.

e.American National Standard Electric Code (ANSI-C1/NFPA-70), for all electrical field wiring.

The oil-fired furnace has been investigated under the UL 307A test standard and the gas-fired furnace under the UL 307B test standard. Both gas and oil fired units are listed by Underwriters Laboratories and described as, “For installation as central furnace special type for single story dwelling.”

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background: The area around the furnace must be kept free and clear of combustible materials, especially papers and rags.

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background: This furnace is not to be used as a construction heater.

1.Definitions of "combustible" and "non-combustible" materials as presented in the 1996 version of the National Fuel Gas Code, ANSI Z223.1-1996/NFPA 70-1996, are as follows:

a. Combustible material:

“...materials made of or surfaced with wood, compressed paper, plant fibers, or other materials that are capable of being ignited and burned. Such materials shall be considered combustible even though flameproofed, fire- retardant treated, or plastered.”

7

Page 8
Image 8
Thermo Products omd-70 service manual a. Combustible material