M. FLUE GAS COMBUSTION ANALYSIS

All installations and services must be performed by qualified service personnel.

range is between 70°F to 100°F. A lower temperature rise usually results in a higher system efficiency.

BURNER COMBUSTION PARAMETERSManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background : If the temperature rise exceeds 100°F, the heat exchanger may fail, voiding the heat exchanger warranty resulting in property damage, personal injury or loss of life.

M. FLUE GAS COMBUSTION ANALYSIS

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background: Burner adjustments must be confirmed by instrumentation. Failure to use accurate or calibrated instrumentation to correctly setup the burner may result in reduced efficiency, sooting, and/or the production of hazardous carbon monoxide gas.

For typical burner combustion analysis results, refer to the table below.

BURNER COMBUSTION PARAMETERS

FURNACE MODEL

OMD-70

FUEL TYPE

#1 OR #2 FUEL OIL

CO (CARBON MONOXIDE)

50PPM OR LESS

CO2 (CARBON DIOXIDE)

11-12%

O2 (OXYGEN)

4.5-6%

SMOKE SPOT RATING

0 TO TRACE

AIR SHUTTER

OPEN TO

ADJUSTMENT

POSITION 35

GMD-85

NATURAL GAS

PROPANE GAS

50PPM OR LESS

50PPM OR LESS

8.75-10%

9.5-11%

5.9-3.8%

6.7-4.5%

N/A

N/A

OPEN TO

OPEN TO

POSITION 4

POSITION 4

N/A = NOT APPLICABLE