MAINTENANCE
Saber Maintenance Section 4-17
©2011 Alamo Group Inc.
MAINTENANCE
TIGHTENING SPINDLE BOLTSThe spindle mounting bolts should be checked and
retorqued daily or every 10 hours of service. Torque
the (6) bolts shown below to 331 ft. lbs.
GREASING PUMP DRIVE SHAFT COUPLERWith engine stopped, ensure drive shaft alignment
by grasping coupler and sliding back and forth.
Coupler should slide freely with approximately 1/8”
of end play. If coupler does not slide freely, inspect
for loose pump mount bolts, or damaged or loose
crank shaft adapter. Inject Lithium-Complex
Extreme Pressure grease conforming to NLGI2-ISO
320 specifications into coupler until grease begins
to protrude from ends. Grease daily or every 8
hours. Do not over grease.