TOA Electronics 600 Table D, Vertical Vent Figures/Tables, Rear Vent - THREE ELBOWS, continued

Models: 600

1 28
Download 28 pages 9.94 Kb
Page 14
Image 14
(continued)

VERTICAL VENT FIGURES/TABLES

(continued)

 

 

TABLE D

 

 

H1

V Minimum

H Maximum

H+H1 Maximum

 

feet

(m)

feet

(m)

feet

(m)

*Ceiling

1

(0.305)

2

(0.610)

5

(1.52)

Firestop/Spacer

2

(0.610)

4

(1.22)

10

(3.1)

(SV4.5BF)

 

3

(0.914)

6

(1.86)

15

(4.65)

 

4

(1.22)

8

(2.48)

20

(6.2)

**Wall

 

V+V1+H+H1 = 40 feet (12.4 m) Max.

 

Firestop/Spacer

 

 

(SV4.5HF)

 

H = 8 feet (2.48 m) Max.

 

V1

 

 

 

 

H + H1 = 20 feet (6.2 m) Max.

 

 

V

Figure 30 - Rear Vent - THREE ELBOWS

*When using Secure Flex, use Firestop/Spacer SF4.5BF

**When using Secure Flex, use Firestop/Spacer SF4.5HF

A Vent Restrictor, as shown in Figure 18, page 10, must be used in this application

*Ceiling

Firestop/Spacer

(SV4.5BF)

H

TABLE E

V MINIMUM

H + H1 Maximum

feet

(m)

feet

(m)

 

 

 

 

1

(0.305)

5

(1.52)

2

(0.610)

10

(3.1)

3

(0.914)

15

(4.65)

4

(1.22)

20

(6.2)

 

 

 

 

H +H1= 20 feet (6.2 m) Max.

V+V1+H+H1 = 40 feet (12.4 m) Max.

Figure 31 - Top Vent - THREE ELBOWS

 

*Ceiling

 

V1

Firestop/Spacer

**Wall

(SV4.5BF)

 

 

Firestop/Spacer

 

 

(SV4.5HF)

 

H

 

H1

V

*When using Secure Flex, use Firestop/Spacer SF4.5BF

**When using Secure Flex, use Firestop/Spacer SF4.5HF

14

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Page 14
Image 14
TOA Electronics 600 Table D, Vertical Vent Figures/Tables, Rear Vent - THREE ELBOWS, Top Vent - THREE ELBOWS, continued