Typical Locations
The location should also be free of electrical, plumbing or other heating/air conditioning duct- ing. These direct vent appliances are uniquely suited for installations requiring a utility shelf positioned directly above the fireplace. Utility shelves like these are commonly used for locat- ing television sets and decorative plants.
To provide for the lowest possible shelf surface use the alternate rear vent outlet with attached venting routed in a way to minimize obstructions to the use of the space above the appliance. Do not insulate the space between the appliance
Model No. |
| Shelf Height inches (mm) |
| ||
|
|
|
| ||
Top Vent - with One 90 Degree Elbow | Rear Vent - Straight Out the Back | ||||
| |||||
|
|
|
|
| |
| Secure Vent | Secure Flex | Secure Vent | Secure Flex | |
46 1/8 (1172) | 47 7/8 (1216) | 35 1/4 (895) | 35 1/4 (895) | ||
46 1/8 (1172) | 47 7/8 (1216) | N/A | N/A | ||
N/A | N/A | 35 1/4 (895) | 35 1/4 (895) | ||
51 1/8 (1298) | 52 7/8 (1343) | 40 1/4 (1022) | 40 1/4 (1022) | ||
51 1/8 (1298) | 52 7/8 (1343) | N/A | N/A | ||
N/A | N/A | 40 1/4 (1022) | 40 1/4 (1022) |
and the area above it. See Figure 3. The
minimum height from the base of the appliance to the underside of combustible materials used to construct a utility shelf in this fashion is shown in the table in Figure 3.
The appliance should be mounted on a fully supported base extending the full width and depth of the unit. The appliance may be located on or near conventional construction materi- als. However, if installed on combustible ma-
Do not insulate the space between the appliance and the area above it.
Shelf Height
(see table)
Do not insulate the space between the appliance and the area above it.
Shelf Height
(see table)
terials, such as carpeting, vinyl tile, etc., a metal or wood barrier covering the entire bot- tom surface must be used.
APPLIANCE AND VENT CLEARANCES
These appliances are approved with zero clear- ance from spacers to combustible materials on all sides (as detailed in Table 2 ), with the following exception: When the unit is installed with one side flush with a perpendictular side wall, the wall perpendicular to the opposite side of the appliance front face must not extend more than five inches beyond the front edge of the unit. In addition, when the unit is recessed, the side walls surrounding the unit must not extend more than five inches beyond the front edge of the unit. Refer to Figure 2.
Figure 3 | Shelf Above Fireplace With Rear Venting | Shelf Above Fireplace With Top Venting | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| BACK |
| 1/2 in. (13 mm) | *Note: | 3 in. (75 mm) above any horizontal/ |
|
| 0 in. (0 mm) spacers | |||
|
|
| inclined vent component. | ||
|
|
|
| ||
| SIDES |
| 1/2 in. (13 mm)** | ||
|
|
|
| ||
|
| 0 in. (0 mm) spacers | **Note: The nailing flange and the cabinet | ||
|
|
| |||
|
|
|
| surfaces directly adjacent to the framing mem- | |
| TOP SPACERS | 0 in. (0 mm) | |||
| ber attached to the nailing flange, are exempt | ||||
|
|
|
| ||
| FLOOR |
| 0 in. (0 mm) | from the 1/2" clearance to combustibles de- | |
|
| fined for the rest of the cabinet sides and back. | |||
|
|
|
| ||
| From Bottom of | 64 in. (1626 mm) | |||
|
|
| |||
| Unit to Ceiling |
|
| ||
|
|
|
| ||
|
|
|
|
|
|
| VENT |
| 1 in. (25.4 mm)* |
|
|
|
|
|
|
| |
| SERVICE CLEARANCES |
|
| ||
|
|
|
|
|
|
| FRONT |
| 3 Feet. (0.9 meters) |
|
|
|
|
|
|
|
|