TOA Electronics 600 L. Install Firestop/Spacer at exterior wall, 1 ¹⁄₄ 32 mm as shown in Figure

Models: 600

1 28
Download 28 pages 9.94 Kb
Page 16
Image 16
L. Install Firestop/Spacer at exterior wall -

If the terminus of the last section is not within this distance, use the telescopic vent section SV4.5LA, as the last vent section. For wall thicknesses greater than that shown in Figure

See Venting Figures for Use Restrictions on the

*Firestop/Spacer (SV4.5HF)

Small Square Horizontal Termination

shown on the exterior side of the

(SV4.5HTSS) and the Horizontal Round

wall. It may also be installed on

Termination (SV4.5HTR).

the interior side.

SV4.5 HTS

Termination

34, refer to table 3 on page 17. This table lists the additional venting components needed (in

12¹⁄₈"

7"

(178)

10¹⁄₂"

Shown.

addition to the termination and adapter) for a particular range of wall thicknesses.

K. Attach termination adapter - Attach the adapter (adapter - SV4.5RCH - provided with the termination) to the vent section or tele- scoping vent section), elbow or appliance col- lar as shown in Figure 33 in the same manner as any SV4.5 vent component (refer to Step E).

L. Install Firestop/Spacer at exterior wall -

When using the square termination, install SV4.5HF (Secure Vent), SF4.5HF (Secure Flex) Firestop/Spacer over the opening at the exterior side of the framing, long side up, with the 3 inch spacer clearance at the top as shown in Figure 34, and nail into place. (The Firestop/Spacer

(308 mm)

5¹⁄₈"

(130 mm)

Adapter

SV4.5RCH

6 to 48 inch Vent Section, Telescopic vent section, Elbow or Appliance Collar

(267mm)

1"

(25.4 mm)

Note: Centerline of Vent Piping is NOT the Same as the Centerline of the Framed Opening.

 

See Figure 9 on page 7

*Firestop/Spacer integral with

for Min. Distance to Base

round termination (SV4.5HTR)

of Appliance.

 

Base of Appliance

 

 

 

 

3"

(76 mm)

may also be installed over the opening at the interior side of the framing.) When using the round termination, a separate firestop/spacer is not required since this termination has inte- gral spacers which provide the same function as a separate firestop/spacer.

M. Install the desired termination -

See the horizontal venting figures for appli- cation restrictions on the round termination (SV4.5HTR) and the small square horizontal termination (SV4.5HTSS).

1. Install the square termination (SV4.5HTS)

or (SV4.5HTSS)- For the last step , from outside

the exterior wall, slide the collars of the termina-

tion onto the adapter (the outer over the outer

and the inner inside the inner) until the termina-

tion seats against the exterior wall surface to

which it will be attached. Orient the housing of

the termination with the arrow pointed upwards.

Secure the termination to the exterior wall. The

horizontal termination must not be recessed

into the exterior wall or siding by more than the

1 ¹⁄₄" (32 mm) as shown in Figure 34.

2. Install the round termination (SV4.5HTR)

– See Figure 35 for an illustration of the round

termination. For the last step, from outside the

exterior wall, slide the collars of the termination

onto the adapter (the outer over the outer and

the inner inside the inner) until the termination

 

Installing the Square Horizontal Termination (SV4.5HTS), Small Square

 

Horizontal Termination (SV4.5HTSS) or Round Horizontal Termination

Figure 33

(SV4.5HTR).

*Note - The SV4.5HTR Horizontal Round Termination may NOT be recessed at all.

 

 

 

 

Minimum wall thickness

 

 

 

 

5 in. (127 mm)

 

 

 

 

Maximum wall thickness

 

 

 

 

9¹ in.(235 mm)

 

Interior Surface of

Exterior Surface of Siding

 

 

Finished Wall

Siding

Maximum

Extent of

Exterior Surface of

 

Vent Run

Sections

Framing

 

Relative

to Exterior

5 in. to 9 ¹ in.

 

Surface

of

Framing

 

Last Vent Section. Use

(127 to 235 mm)

 

 

 

T e l e s c o p i c V e n t

 

 

Section (SV4.5LA), If

 

 

Necessary

 

 

 

 

 

 

SV4.5HTS

 

 

 

 

Square Termination

 

SV4.5HTS

 

 

Shown

 

 

 

 

 

Square Termination

 

 

shown

 

Adapter

 

 

 

 

 

Stucco

 

 

SV4.5RCH

 

 

 

 

*1¹⁄₄" Maximum Recess of

 

 

 

 

 

 

 

 

Either Square Termination into

See Venting Figures for Use Restrictions on the Small Square

Exterior Finishing Material

Horizontal Termination (SV4.5HTSS) and the Horizontal Round

 

Termination (SV4.5HTR).

 

 

 

Venting Connection and Exterior Wall Recessing of the Horizontal Square Termination (SV4.5HTS),Small Square Termination (SV4.5HTSS) or Round Termination ((SV4.5HTR).

Figure 34

seats against the exterior wall surface to which

it will be attached. Orient the housing of the

termination with the arrow pointed upwards.

Secure the termination to the exterior wall.

SFHRK Snorkel Cap –The snorkel cap is de- signed to be fitted into a basement window box. The SFHRK cap is for use with flex vent pipe. The vertical distance between the inlet and outlet of the cap is 28 in. (711 mm).

The SV4.5HTR Round Termination may not be used when the appliance is vented di- rectly out the wall from the rear (as shown in Figures 36 or 37 on page 17). Do Not recess the SV4.5HTR round termination at all.

See Horizontal Vent- ing Figures and Tables for Use Restrictions

 

SV4.5HTR Horizontal

Figure 35

Round Termination

16

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Page 16
Image 16
TOA Electronics 600 L. Install Firestop/Spacer at exterior wall, M. Install the desired termination, SV4.5HTR