Toshiba CS8560D specifications Sync reset mode Under internal sync

Models: CS8560D

1 41
Download 41 pages 47.74 Kb
Page 10
Image 10

(c)V-reset mode (Under internal sync / external sync --- No VD IN)

Exposure starts at the timing of TRIG signal IN. After each exposure is completed, the camera outputs video immediately by resetting VD. (HD is not reset)

1/60s Non-interlace

Automatically returns to normal shutter if fixed H level (after approx. 1/6s)

TRIG IN not acceptable for

TRIG IN

1V after mode chenge

(Positive)

CCD Exposure

Exposure time

(E-shutter speed or

pulse width)

VIDEO OUT

 

Definite

VD,V-SYNC pause during standby

VD,V-SYNC output for 1V only

 

WEN OUT (Standard)

WEN OUT [Option]

Normal shutter

Random trigger shutter

Normal shutter

1/120s 2:1 Interlace

Irrespective of TRIG IN phase, the camera always outputs ODD field image.

Automatically returns to normal shutter if fixed H level (after approx. 1/6s)

TRIG IN not acceptable for

TRIG IN

1V after mode chenge

(Positive)

CCD Exposure

VIDEO OUT

ODD

EVEN

Exposure time

ODD

ODD

(E-shutter speed or

image

image

pulse width)

image

image

 

 

 

 

ODD

EVEN

 

ODD

ODD

VD,V-SYNC pause during standby

Definite

VD,V-SYNC output for 1V only

 

WEN OUT (Standard)

WEN OUT [Option]

Normal shutter

Random trigger shutter

Normal shutter

(d) SYNC reset mode (Under internal sync)

Exposure starts at TRIG signal input timing, resets HD, and outputs video immediately after exposure by resetting VD.

*Available under FIX mode only. 1/60s Non-interlace

Automatically returns to normal shutter if fixed H level (after approx. 1/6s)

TRIG IN not acceptable for

TRIG IN

1V after mode chenge

(Positive)

CCD Exposure

Exposure time

(E-shutter speed)

VIDEO OUT

VD,V-SYNC pause during standby

Definite

VD,V-SYNC output for 1V only

 

 

WEN OUT (Standard)

WEN OUT

[Option]

Normal shutter

Random trigger shutter

Normal shutter

10

D4130891A

Page 10
Image 10