5-2. Line-Lock Control

Matching the vertical synchronization with the power frequency is called the Line-Lock.

This function is activated when the SYNC menu is selected to LL.

When two or more cameras are switched by the video switcher for viewing by a monitor TV, the vertical sync. phase can be locked with the power frequency, and a stable vertical sync. is obtained without being disturbed at the time of switching.

CAMERA1

MONITOR TV

CAMERA2

VIDEO SWITCHER

TO 24V AC UL Listed

Class 2 power supply

Note:

The camera is synchronized to the power frequency of 60 ±1 Hz covering a normal fluctuation of the power frequency. However, the camera may not cover a large fluctuation caused from the power generated by an engine generator, etc.

It takes about 10 seconds or more until a stable synchronization is obtained after the power is turned on. This is normal, because several seconds are required to stabilize the camera against power noise.

Refer to "7. LINE-LOCK PHASE" for adjustment.

5-3. Operation

1.Mount the lens to the camera.

2.Mount the camera to the camera mount.

Caution: If the lens weight is more than 2.2 lbs (1 kg) mount the lens to the camera mount. Refer to section 6 for lens types and connection.

3.Connect the cables and support equipment to obtain a picture.

4.Adjust the lens aperture (if applicable).

- 8 -