4. CONNECTIONS

Notes on connecting

¥Power plugs of connected equipment must be disconnected before camera installation.

¥A 75-ohm coaxial cable with connector (3C-2V or 5C-2V) is required for standard connection.

¥For details of wiring and operation of equipment to be connected, refer to their operation manuals.

¥A power supply with cable, connectors and coaxial cable are not supplied with the camera.

4-1. Basic connection single system configuration

Display Monitor

BNC Connector

1Red Connector

24V AC UL Listed Class 2 power supply or

12V DC power supply.

2Black

(*) Recommended power cord is a minimum wire size of 18 AWG.

Connector

24V AC

12V DC

 

 

 

1Red wire

24V AC (L)

Positive

 

 

 

2Black wire

24V AC (N)

Negative

 

 

 

CAUTION: Never input 24V AC and 12V DC at the same time.

Do not overload power supply

The recommended power supplies for this camera are 6 watt minimum for each 24V AC UL Listed Class 2 power supply or 12V DC power supply.