4-2. Line lock Control

¥Matching the vertical synchronization with the power frequency is called the Line Lock.

¥To activate the line lock, set the LL switch to ON.

1 2 3 4

ON

OFF

LineLock

¥When two or more cameras are switched by the video switcher for viewing with a display monitor the vertical synchronization phase can be locked to the power frequency for a stable vertical synchronization.

Video Switcher

Display Monitor

BNC Connector

 

Camera 1

Connector

To 24V AC UL Listed

Class 2 power supply.

Camera 2

¥ When connecting to DC power supply, the Line Lock function is not activated.

Note:

¥The camera is synchronized to the power frequency of 60 ±1 Hz covering a normal fluctuation of the power frequency. However, the camera may not cover a large fluctuation caused from the power generated by a generator, etc.

¥It takes approximately 10 seconds or more until a stable synchronization is obtained after the power is turned on. This is normal, because several seconds are required to stabilize the camera against power noise.

¥Refer to section 7. "LINE LOCK PHASE" for adjustment instructions.