( 3 ) Using the unit with external sync signal

When adjusting H (horizontal) phase refer to the item "7.2 (5) (5.1) Adjusting horizontal phase".

(3. 1) H (horizontal) phase adjustment

Observe the external sync signal and the video signal output waveform of the unit with a dual trace oscilloscope, and ad- just H phase so that the H phases match.

External

Sync. signal Match

the phase.

Camera

Video output

( 4 ) Changing HD/VD input/output

(1)Put off 6 screws both on flank/top of camera chassis.

(2)Change internal switch SJ01(HD/VD).

HD/VD OUTPUT

SJ01

HD/VD INPUT high-impedance HD/VD INPUT 75(factory setting)

7. 4 Synchro. Scan Operation

The shutter speed can be set by the horizontal scanning period (1H) or by the frame.

( 1 ) Setting by 1H

1/525H to 524/525H stands for the setting by the 1H and the shutter speed can be set by the 1H (31.8 ms).

( 2 ) Setting by the frame

1FRM to 512FRM stand for the setting (long period exposure) by the frame.

The video signal stored during the frame period set is output as 1 frame video image at a frame interval specified.

VD output

Video output

Index output

(INDEX)

n

(4FRM setting)

n+1

23

Page 23
Image 23