Toshiba IK-TF5 1P SR 1 Pulse Sync Reset, Pulse Trigger SYNC-RESET Picture Output Timing

Models: IK-TF5

1 36
Download 36 pages 31.73 Kb
Page 26
Image 26

( 2 ) 1P SR (1 Pulse Sync Reset)

Charge begins to accumulate after the trigger input to the RGB terminal, the vertical sync signal is reset and field images are output.

(2. 1) 1 Pulse Trigger SYNC-RESET Picture Output Timing

Negative polarity mode

Trigger*1

Positive polarity mode

About 1 s

Exposure period*2

Exposure completion

to 1H*3

VD OUT

Video output

VIDEO INDEX

525H (Partial scanning OFF)

175H (Partial scanning ON)

*1: Externally input signal

*2: Exposure time is determined by the setting of "(1.3) Changing each setting in E.TRG mode".

*3: VD is generated after 0 to 1H following the completion of the exposure period and the video is synchro- nized to this and output.

Note:

When the next trigger is input before completion of the output of the video corresponding to the trig- ger, there will be an effect on the video.