( 2 ) 1P SR (1 Pulse Sync Reset)
Charge begins to accumulate after the trigger input to the RGB terminal, the vertical sync signal is reset and field images are output.
(2. 1) 1 Pulse Trigger SYNC-RESET Picture Output Timing
Negative polarity mode
Trigger*1
Positive polarity mode
About 1 ∝ s
Exposure period*2
Exposure completion
0to 1H*3
VD OUT
Video output
VIDEO INDEX
525H (Partial scanning OFF)
175H (Partial scanning ON)
*1: Externally input signal
*2: Exposure time is determined by the setting of "(1.3) Changing each setting in E.TRG mode".
*3: VD is generated after 0 to 1H following the completion of the exposure period and the video is synchro- nized to this and output.
Note:
When the next trigger is input before completion of the output of the video corresponding to the trig- ger, there will be an effect on the video.
26