(1. 3) Changing the setting in E.TRG mode

The E.TRG has five modes; 1P SNR, 1P SR, PW SNR, PW SR, RR.

First move the “” to MODE and select E. TRG, then move the “” to E.TRG and select the desired E.TRG mode.

( 1.3. 1) Changing the setting in 1P SNR mode

Move up down

 

Select the desired

by pushing

 

value by pushing

MENU UP, DOWN

 

DATA UP, DOWN

SHUTTER

 

MODE

E.TRG

E.TRG

1P SNR

TRG.P

 

EXP.

30ms

OUT.P

OFF

<MODE = E.TRG E.TRG = 1P SNR>

Shutter mode MANU, SS, E.TRG, AUTO

E.TRG mode

1P SNR, 1P SR, PW SNR, PW SR, RR

• Input trigger pulse setting at 1P SNR and 1P SR

Input trigger pulse : positive polarity Input trigger pulse : negative polarity

• Exposure time setting at 1P SNR and 1P SR

 

0.01 ms 0.02 ms 0.4 ms 1 ms

20 ms 30 ms

0.01 ms

0.02 ms

0.1 ms

1 ms

2 ms

step

step

step

step

step

• Partial scanning switchPART switch

OFF, 40fps, 42fps, 50fps, 60fps, 70fps, 80fps, 90fps E.40fps, E.42fps, E.50fps, E.60fps, E.70fps, E.80fps, E.90fps

(a) Changing the polarity of the input trigger pulse setting

aaMove the “” to TRG.P by pushing [MENU UP], [MENU DOWN] buttons. aaSelect either , by pushing [DATA UP], [DATA DOWN] buttons.

(b) Changing 1P SNR exposure time setting

aaMove the “” to EXP. by pushing [MENU UP], [MENU DOWN] buttons. aaSelect the exposure time by pushing [DATA UP], [DATA DOWN] buttons.

(c) Changing the partial scanning setting

aaMove the “” to OUT.P by pushing [MENU UP], [MENU DOWN] buttons. aaSelect the mode by pushing [DATA UP], [DATA DOWN] buttons.

caaMove “” to the current value by pushing [MENU UP], [MENU DOWN] buttons. daaSelect a desired settings by pushing [DATA UP], [DATA DOWN] buttons.

* The preset value of partial scanning is not displayed, when OUT.P is OFF.