7. 4 E. TRG (External trigger)
Charge begins to accumulate after the trigger input to CC1 of the DIGITAL terminal, and 1 frame images are output. There are four modes: 1P SNR, 1P SR, PW SNR, PW SR.
( 1 ) 1P SNR (1 Pulse Trigger Sync Non Reset)
Charge begins to accumulate after the trigger input to CC1 of the DIGITAL terminal, and 1 frame images are output.
(1. 1) 1 Pulse Trigger
Trigger*1
Negative polarity mode
Positive polarity mode
About 1 ∝s |
|
Exposure period*2 | Exposure period*2 |
External HD IN*1
External VD IN*1
About 1H
(Internal VD)
RGB data
(video interval image)
FVAL
LVAL,
DVAL
*4
28H (Partial scanning OFF)
25H (Partial scanning 40fps)
27H (Partial scanning 42fps)
33H (Partial scanning 50fps)
39H (Partial scanning 60fps)
43H (Partial scanning 70fps)
46H (Partial scanning 80fps)
48H (Partial scanning 90fps)
The internal VD falling edge is within the exposure period and thus video is not output. *3
*1: External input signal
*2: Exposure time is determined by the setting of “7. 2 (1.3) Changing the setting in E.TRG mode”.
*3: Video is output at the falling edge of the internal VD following completion of the exposure period. The video and FVAL/LVAL/DVAL have a paired relationship.
*4: When NR is set to ON, 1H is increased.
Note:
When the next trigger is input before completion of the output of the video corresponding to the trigger, there will be an effect on the video.
27