7. 5 Partial Read

( 1 ) Partial Scanning OFF (All pixels scanning)

In this mode, every pixels independent signal is output from the DIGITAL connector each 1/29.2s.

Video interval

image

1/29.2s (796H)

( 2 ) Partial Scanning ON

In this mode, the pixel signal of the vertical center portion of the image is output from the DIGITAL connector.

In the E.fps mode, the partial scanning and all the pixels scanning can be switched by the DIGITAL terminal (CC2: partial scanning control signal).

CC2

E.40fps

E.42fps

E.50fps

E.60fps

 

 

 

 

 

‘L’

Partial scanning 40fps

Partial scanning 42fps

Partial scanning 50fps

Partial scanning 60fps

 

 

 

 

 

‘H’

All pixels scanning

All pixels scanning

All pixels scanning

All pixels scanning

 

 

 

 

 

CC2

E.70fps

E.80fps

E.90fps

 

 

 

 

 

 

‘L’

Partial scanning 70fps

Partial scanning 80fps

Partial scanning 90fps

 

 

 

 

 

 

‘H’

All pixels scanning

All pixels scanning

All pixels scanning

 

 

 

 

 

 

Video interval

image

1/40s (580H):When 40fps is selected 1/42s (553H):When 42fps is selected 1/50s (465H):When 50fps is selected 1/60s (387H):When 60fps is selected

1/70s (332H):When 70fps is selected 1/80s (290H):When 80fps is selected 1/90s (258H):When 90fps is selected

32