10.BEFORE MAKING A SERVICE CALL
Symptom | Items to be checked |
No image | • Is the power supplied correctly? |
| • Is the lens iris adjusted correctly? |
| • Are the cables connected correctly? |
| • Is the shutter mode set correctly? |
| • Is the image process equipment set correctly? |
|
|
Poor color | • Is the monitor adjusted correctly? |
•Is the white balance of the camera adjusted correctly?
•Is there enough illumination?
11.SPECIFICATIONS
Power supply | DC 10V ~ DC 13.2V |
Power consumption | Approx. 3.1W (When the DC power supply is 12V) |
|
|
RGB, 3CCD | |
Image sensor | 1/3inch All pixels CCD |
| (Effective pixels Horizontal : 1034, Vertical : 779) |
|
|
Scanning System | Progressive scan |
Video output pixels | Horizontal pixels : 1024, Vertical : 768 |
|
|
Pixel clock frequency | 29.5MHz |
|
|
Sync signal frequency | Horizontal : 23.229kHz, Vertical : 29.18Hz |
Sync system | Internal/External (Automatic switching) |
|
|
Sensitivity | F6.8 standard (2000 lx, 3000K) |
Minimum illumination | 14 lx (F2.2, Sensitivity + 18 dB, 3000K) |
|
|
Lens mount | C mount (flange back : 17.526 mm |
|
|
Ambient temperature | 0 to 40°C (32 to 104°F) |
Ambient humidity | Less than 90% |
|
|
Weight | Approx. 158g (0.338lbs) |
|
|
External dimension | 44 (W) x 44 (H) x 78 (D) mm |
| (1.73” (W) x 1.73” (H) x 3.07” (D)) (except for protruded portion) |
|
|
White balance | AWB (Automatic white balance), MANUAL (Manual) |
|
|
Gain | MANUAL (Manual), OFF (0 dB) |
|
|
Partial scanning | 40fps, 42fps, 50fps, 60fps, 70fps, 80fps, 90fps |
|
|
Output signal | |
Sync signal output | FVAL, LVAL, DVAL (Positive polarity) |
| Pixel Clock |
|
|
External sync input | HD : CC3 (LVDS input) Negative polarity |
| VD : CC4 (LVDS input) Negative polarity |
|
|
External trigger input | CC1 (LVDS input), More than 2 μs pulse width |
|
|
Partial scanning control | CC2 (LVDS input) |
signal input |
|
|
|
Interface | Serial data interface : Ser TC (RXD), Ser TFG (TXD) |
The designs and specifications are subject to change without notice.