AIR CONDITIONER OPERATION AND PERFORMANCE

AIR CONDITIONER OPERATION AND PERFORMANCE

Three-minute protection feature

A protection feature is provided that prevents the air conditioner from being activated for approximately 3 minutes when it is restarted immediately after operation or when the power supply switch is set to on. This is used to protect the machine.

Heating characteristics

Preheating operation

The air conditioner does not deliver warm air immediately after it is started.

Warm air flows out after approximately 5 minutes when the indoor heat exchanger has warmed up.

Warm air control

When the room temperature reaches the temperature setting, the fan indoor speed is automatically reduced. The outdoor unit is stopped at this time.

Defrosting

If frost has formed on the outdoor unit during the heating operation, defrosting is started automatically (for approximately 5 to 10 minutes) to maintain the heating effect.

The fans in both the indoor and outdoor units stop during the defrost operation.

During the defrost operation, defrosted water is drained from the bottom plate of the outdoor unit.

Heating capacity

In the heating operation, heat is absorbed from outdoors and released into the room. That is called the heat pump system. When the outdoor temperature is too low, usage of another heating apparatus in combination with the air conditioner is recommended.

Consideration for accumulated snow

Select the position for the outdoor unit where it will not be subjected to snow drifts, accumulation of leaves or other seasonal debris. It is important that the air flow of the outdoor unit is not blocked as this will result in reduced heating or cooling performance. During the heating mode and at sub-zero temperatures, the water drained off the outdoor unit as a result of the automatic defrost may accumulate and freeze. It is important that adequate drainage or a soak-way be provided.

CAUTION (RAS-***-ND model only)

A heater is installed on the base plate of the outdoor unit. When the outside air temperature is low, the heater runs to warm the base plate even if the unit is not operating so that snow does not accumulate inside the outdoor unit. Do not use the supplied drain nipple for draining water. Drain the water from all the drain holes directly. Provide a space of at least 50 cm under the outdoor unit so that the draining water does not freeze and block the drain holes.

Power failure

Power failure during operation stops the unit completely.

The OPERATION indicator (green) on the indoor unit starts flashing when power is restored.

To restart operation, push the Three-minute protection feature button on the remote controller.

Lightning or a car wireless telephone operating nearby may cause the unit to malfunction. Turn the power supply switch off and then on again. Push the Heating characteristics button on the remote controller to restart.

Air conditioner operating conditions

For proper performance, operate the air conditioner under the following temperature conditions.

Cooling operation

Outdoor temperature:

–10°C to 46°C

 

Room temperature:

21°C to 32°C

CAUTION

Room relative humidity — less than 80%. If the air conditioner operates outside this range, the surface of the air conditioner may attract condensation.

Heating operation

Outdoor temperature:

–15°C to 24°C

 

Room temperature:

Less than 28°C

 

 

 

Dry operation

Outdoor temperature:

–10°C to 46°C

 

 

 

 

Room temperature:

21°C to 32°C

 

 

 

8°C Heating

Setting temperature:

5°C to 13°C

If the air conditioner is used in conditions other than above, the safety protection functions may be activated.

23

EN

Page 25
Image 25
Toshiba RAS-07PKVP-E Air Conditioner Operation And Performance, Three-minuteprotection feature, Heating characteristics

FAQ

What is the purpose of the three-minute protection feature?

The three-minute protection feature prevents the air conditioner from being activated for approximately 3 minutes when it is restarted immediately after operation or when the power supply switch is set to on to protect the machine.

How does the air conditioner handle heating characteristics?

The air conditioner does not deliver warm air immediately after it is started. Warm air flows out after approximately 5 minutes when the indoor heat exchanger has warmed up. When the room temperature reaches the temperature setting, the fan indoor speed is automatically reduced and the outdoor unit is stopped.

What are the recommended operating conditions for the air conditioner?

For proper performance, operate the air conditioner under specific temperature conditions for cooling, heating, dry operation, and 8C heating.