6F3B0360 |
5.Specifications
The section describes the specifications of the Active Star Coupler.
(1)General specifications
General specifications of Active Star Coupler are given below.
| Item | Specification | ||
| Voltage | Rating | 100/110 V AC, 50/60 Hz | |
|
|
| 200/220 V AC, 50/60 Hz | |
|
| Fluctuation range | 85 to 132 V AC, 47 to 66 Hz | |
Power |
|
| 170 to 250 V AC, 47 to 66 Hz | |
Supply | Power consumption | about 10 VA | ||
| Retentive power interruption | Resuming to normal operation within 10 ms | ||
| Insulation rating | 1500 V AC for 1 minute | ||
| Fuse rating | |||
| Tempe- | Operating | 0 to +55°C (unit ambient temperature) | |
| rature | temperature |
| |
|
| Storage | −20 to +75°C (unit ambient temperature) | |
|
| temperature |
| |
Environ- | Humidity | 20 to 90% RH, no condensation | ||
ment | Vibration | Conforming to JIS C0911 | ||
|
|
| ∙ Power OFF, Frequency 16.7 Hz, Displacement 3 mm | |
| Atmosphere | Free from corrosive gas | ||
| Dust | Not more than 1 mg/m3 | ||
| Ground | Grounding resistance 100Ω or less | ||
External dimensions | 390 (W) × 200 (D) × 70 (H) mm | |||
Weight |
|
| approximately 3.0 kg | |
Cooling |
|
| Natural air cooling | |
Installation position | Horizontal (unacceptable of upside down or vertical | |||
position) | ||||
|
|
| ||
|
|
| Table 5.1 |
TOSLINE S20 | 11 |