11. PROGRAMMING PROCEDURES
11.2 PLU DATA SETTING

11- 5

11.2 PLU DATA SETTING

Menu Page:1

Item No.: 1

Setting or changing the contents of PLU (PLU#, UPC#, Commodity Name, etc).

b

Enter PLU#
(max. 6 dig.) Enter UPC#
(Max. 6 dig.)
Enter commodity name.
(max. 32 chars. 4 lines)
In what mode
is PLU used?
Enter quantity for that
price. (Max. 2 dig.) Enter unit price.
(max. 4 dig.)
BY COUNT
WEIGH
or FIX
<MENU>
Page 1 1AUTO
CODE

Set auto code

for the UPC#

ENTER
NEXT
PLU
SET
NEXT
ENTER ENTER ENTER
ENTER ENTER
Is status
of initial set
#8-2?
1
0

Set tare limit.

Max. 2 lb (US)
Max. 1Kg/2.205 lb (CA/QR) ENTER
Is status
of initial set
#1-6?
1
0
Is status
of initial set
#26-4?
1
0
Enter flag of
unit price.
ENTER Enter shelf life.
(Max. 3 dig.)
ENTER
Is status
of initial set
#7-8?
1
0
Enter PERIOD OF
RELISH (Max. 3 dig.) ENTER
Is status
of initial set
#8-1?
2
0 or 1
Select
compulsory tare
Is status
of initial set
#23-1?
1
0
Enter tare wignt.
Max. 2lb (US)
Max. 1 kg/2.205 lb (CA)
ENTER
Is status
of initial set
#1-5?
1
0
Selection Mode Flag
0: Weight
1: By Count
2: Fix Price
ENTER
Is status
of initial set
#10-5?
1
0
Safe Handing
Instruction
0: Non Print
1: Print
ENTER
Enter current
PLU# Enter new
PLU#
CHANG
E PLU ENTER ENTER
Enter
PLU#
DELETE
PLU ENTER YN

or

The setting label is issued.
TEST
Status
of initial set
#8-7/28-4?
1
0
Set tare %
(Max. 99.9%)
ENTER
The memory file is sorted when a
memory full error occurs.
(Not Sorting)
(Sorting)

Y

Any key
except Y
b
PROG.
ESC.
<MENU>

Page 1

Main

<MENU>
Is status
of initial set
#12-4?
2
0 or 1
Enter discount price
or rate.
(Price: Max. 5 digit
Rate: Max. 3 digit)
ENTER
Is status
of initial set
#9-4?
1
0
Enter LOGO #.
(#0 - 26)
or (#0 - 99)*ENTER
(Price %)
See
NOTE 7.
*: Selectable by the initial setting #10-7.
(SL-9000N only)