11. PROGRAMMING PROCEDURES

11.15 LON SYSTEM

Data Transmission

 

The following data is down-line-loaded.

 

Page 1: (0). All (PLU+ING+NUTRI)

Page 2: (0). SPEED KEY

(1). PLU

(1). LOGO

(2). ING.

(2). VENDOR

(3). NUTRITION

(3). FREE FORMAT

(4). U. PRICE

(4). ADDRESS (SL-9000N only)

(5). DATE/TIME

(5). INITIAL (#0 - #19, SL-9000N only)

(6). MESSAGE LINK (Message)

(9). CHANGE PAGE

(7). LOCK SCALE (Check the LON cable)

(8). OPEN SCALE (Release the lock after checking the LON cable.)

(9). CHANGE PAGE

n

Enter a DLL data.

ENTER

p

Release the scale from the error.

0:CANCEL

1:RETRY

2:CONTINUE

NOTE: DLL is performed automatically in the following two ways. It is selectable by the Initial Settings #0-6 and #0-7.

(1)LOCK SCALE method

Step 1: “LOCK SCALE” is sent. (*1)

Step 2: Selected data is sent.

(*2)

Step 3: “OPEN SCALE” is sent.

 

*1: If an error occurs during step 1, the error terminal ID# is indicated.

Select “cancel”, “retry” or “continue” to release the terminal from an

error.

 

 

 

cancel:

Quits the operation after sending “OPEN SCALE”

retry:

Tries to send “LOCK SCALE” again.

continue: Ignores the error terminal and starts DLL.

*2: If an error occurs during step 2, the error terminal ID# is indicated.

Press the

CLEAR

 

key to return to the DLL data selection menu.

(2) Background DLL

 

 

 

Step 1: Selected data is sent.

(*3)

*3: If an error occurs, the error terminal ID# is indicated. Press the CLEAR key to return to the DLL data selection menu.

11-25

Page 50
Image 50