2.9 Touch Pad Troubleshooting 2 Troubleshooting Procedures

2.12 PCMCIA Troubleshooting

START
Do errors occur during
SYCARD test?
Perform PCMCIA socket
replacement check
(Procedure 2)
Replace system board
END
PCMCIA unit is
not faulty.
Perfo rm SYCARD test
(Procedure 1)
No
Yes

Figure 2-12 PCMCIA troubleshooting process

Tecra A3/S2 Series Maintenance Manual 2-29