NAMES
PART
PART
NAMES
13

DIP SWITCHES

DIP switch ON or OFF is set as follows:
FD07
DSW 2
DSW 1
After changing the setting of a DIP switch, turn the power switch off once and then
turn it back on.
*: Factory-setting made before shipping
No. Function OFF ON
8 PC connection *Standard Two-way communica-
tions
7 Not used *Select OFF.
6 Not used *Select OFF.
5 Not used *Select OFF.
4Satin stitch width
adjustment
*Adjustment for stitch
width of 1.5 mm or
larger
Adjustment for stitch
width of 0.6 mm or larger
3
Satin stitch adjust-
ment mode selec-
tion
*Collective adjustment
for X- and Y-axis
Independent adjust-
ment for X- and Y-axis
2Program install
device selection *FD PC
1 Installation mode *Normal mode Installation mode if
DSW1-1 is ON.
No. Function OFF ON
8 Start-up speed *Standard High speed
7 Not used *Select OFF.
6 Not used *Select OFF.
5 Not used *Select OFF.
4
Hoop travel direc-
tion: Arrow symbols
and actual travel
direction
*Same direction as indi-
cated by the arrow
symbol
Opposite to the direction
indicated by the arrow
symbol
3 Buzzer sounds *10 times 1 time
2Language in LCD
display *English Japanese
1 Test mode *Normal operation Test mode
Access to the Embroidery Information
In the test mode, you can access to the following
information:
Accumulated number of embroidered pieces of cloth
Accumulated number of stitches
Accumulated number of error displays and others
Consult your TOYOTA dealer for more details.

1 2 3 4 5 6 7 8

ON

1 2 3 4 5 6 7 8

ON
DSW1
DSW2